Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHEMATICS OF THE SOUTH RESTORATION DIVISION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHEMATICS OF THE SOUTH RESTORATION DIVISION, INC. in 2035 FLA A1A, INDIAN HARBOUR BEACH, FL 32937 (NAICS 238160). OSHA activity number 340897305.

Watch Chematics OF THE South Restoration Division, INC. — free Get an email when a new federal OSHA severe-injury report for Chematics OF THE South Restoration Division, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2035 FLA A1A
City
INDIAN HARBOUR BEACH
State
FL
ZIP
32937
Mailing
166 CENTER ST SUITE 201, CAPE CANAVERAL, FL 32920
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
25
Ownership type
A

5 citations on file for this inspection.

1926.451 D03 X

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $2200.00
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle:  a. On the roof, single wire tiebacks were installed at angles while supporting swing stage scaffolds, exposing employees to a 27 foot fall hazard, on or about 9/2/2015.
Recent events (1)
  • — Z (S) $2200

1926.451 G01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:  a. On the swing stage scaffold, employees were not wearing their personal fall arrest equipment which was hanging on the guardrail system, exposing employees to a 27 foot fall hazard, on or about 9/2/2015.
Recent events (1)
  • — Z (S) $3080

1926.451 G03 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system:  a. On the roof, two vertical lifelines, one wire rope tieback, and one additional line were attached to the same anchorage point, exposing employees to 27 foot fall hazard, on or about 9/2/2015.
Recent events (1)
  • — Z (S) $3080

1926.502 D11

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $1870.00 · Current $1870.00
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:  a. On the roof, chaffing gear was not provided for the lifelines, exposing employees to a 27 foot fall hazard, on or about 9/2/2015.
Recent events (1)
  • — Z (S) $1870

1926.451 D12 IV

Other-than-serious 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(d)(12)(iv): Clips shall be inspected and retightened to the manufacturer's recommendations at the start of each workshift thereafter:  a. On the roof, the wire rope clips used to secure the outriggers supporting the swing stage scaffold were not checked for the correct tightness at the start of the workshift, exposing employees to 27 foot fall hazard, on or about 9/2/2015.
Recent events (1)
  • — Z (O) $0

View CHEMATICS OF THE SOUTH RESTORATION DIVISION, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340897305.