NEW HAVEN, CT —
OSHA Inspection: NYDC BEAUTY SUPPLY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NYDC BEAUTY SUPPLY, INC. in 55 GRANT ST., NEW HAVEN, CT 06519 (NAICS 424210). OSHA activity number 340904226.
Where did this inspection happen?
- Establishment
- NYDC BEAUTY SUPPLY, INC.
- Site address
- 55 GRANT ST.
- City
- NEW HAVEN
- State
- CT
- ZIP
- 06519
- Mailing
- 3365 FARRINGTON ST., FLUSHING, NY 11354
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424210
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. Establishment: The employees, who were required to work on the second floor storage mezzanine of the warehouse were not protected from the hazard of falling over nine (9) feet to the floor by the use of standard railing system or an equivalent.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.23 D01 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side. Establishment: The mobile stairway, having 8 steps and used by employees to access the second floor was not equipped with one stair railing on either side.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Establishment: The employer did not ensure through proving information and training and performing evaluation that the operator of the electric powered forklift truck (PIT) was competent to operate the PIT safely at all times.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
More inspections in this industry (NAICS 424210)
AUSTIN, MN—2026-06-29
111494 - SMART-FILL MANAGEMENT GROUP INC
ALBANY, OR—2026-06-02
317744363 - VETERINARY SERVICES INC
ROGERS, MN—2026-06-01
111357 - JAYS COMPANY INC
NORTON SHORES, MI—2026-03-12
PRINOVA USA LLC, DBA PRINOVA PARTICLE TECHNOLOGIES
SPRINGVILLE, UT—2026-03-09
MIXHERS
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340904226.