Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPE UTILITY CONTRACTORS FD LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SPE UTILITY CONTRACTORS FD LLC in 1431 S. KINGSWAY RD, SEFFNER, FL 33583 (NAICS 237130). OSHA activity number 340906700.

Watch SPE Utility Contractors FD LLC — free Get an email when a new federal OSHA severe-injury report for SPE Utility Contractors FD LLC is published. One employer, no account, unsubscribe in one click.
Site address
1431 S. KINGSWAY RD
City
SEFFNER
State
FL
ZIP
33583
Mailing
8801 MAISLIN DRIVE, TAMPA, FL 33673
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
150
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $6000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to hazard of electrical shock or electrocution in that the effectiveness of the insulation was not tested:    a) For employees working from the bucket of the Altec bucket truck, model AA600L, serial number 0405-V1125, US DOT 981578, on or about September 9, 2015, the employer had not conducted a dielectric l test on the bucket truck at least annually. The last dielectric testing was done on June 28, 2014.
Recent events (3)
  • — F (O) $6000
  • — C (S) $7000
  • — Z (S) $7000

1926.960 C01 I

Deleted Serious Gravity 10 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1926.960(c)(1)(i): The employer did not establish minimum approach distances (MAD) no less than the distances computed by Table V-2 for ac systems:  On or about September 9, 2015 the employer did not establish a minimum approach distance (MAD) for energized work on or near 13Kv (phase to phase) power lines that was equal to or greater than the 2.13 feet required by Table V-2.    Or, in the alternative:    29 CFR 1910.269(l)(3)(i): The employer did not establish minimum approach distances not less than the distances computed by Table R-3 for ac systems:  a) On or about September 9, 2015 the employer did not establish a minimum approach distance (MAD) for energized work on or near 13Kv (phase to phase) power lines that was equal to or greater than the 2.13 feet required by Table R-3.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1926.960 C01 III

Serious Gravity 10 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $7000.00
1926.960(c)(1)(iii): The employer did not ensure that no employee approached or took conductive objects closer to exposed energized parts than the employer's established minimum approach distance (MAD) or the distance computed by Table V-2:      On or about September 9, 2015 the employer did not ensure that employees exposed to 13Kv phase to phase line voltage maintained a MAD of 2.13 feet as required by Table V-2 or that employees were insulated from the energized part by rubber insulating gloves or rubber insulating gloves and sleeves worn in accordance with standard 1926.960(c)(2) which constitutes insulation of the employee from the energized part upon which the employee is working when the employee did not have control of the part in a manner sufficient to prevent exposure to un-insulated portions of the employee's body. Likewise, energized parts were not insulated from the employee and from any other conductive object at a different potential.    Or, in the alternative:    29 CFR 1910.269(l)(3)(iii): The employer did not ensure that no employee approached or took any conductive object closer to exposed energized parts than the employer's established minimum approach distance or the distance computed by Table R-3.    On or about September 9, 2015 the employer did not ensure that employees exposed to 13Kv phase to phase line voltage maintained a minimum approach distance (MAD) of 2.13 feet as required by Table R-3 or that employees were insulated from the energized part by rubber insulating gloves or rubber insulating gloves and sleeves worn in accordance with standard 1910.269(l)(4) which constitutes insulation of the employee from the energized part upon which the employee is working when the employee did not have control of the part in a manner sufficient to prevent exposure to un-insulated portions of the employee's body. Likewise, energized parts were not insulated from the employee and from any other conductive object at a different potential.
Recent events (3)
  • — F (S) $7000
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340906700.