SEFFNER, FL —
OSHA Inspection: SPE UTILITY CONTRACTORS FD LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SPE UTILITY CONTRACTORS FD LLC in 1431 S. KINGSWAY RD, SEFFNER, FL 33583 (NAICS 237130). OSHA activity number 340906700.
Where did this inspection happen?
- Establishment
- SPE UTILITY CONTRACTORS FD LLC
- Site address
- 1431 S. KINGSWAY RD
- City
- SEFFNER
- State
- FL
- ZIP
- 33583
- Mailing
- 8801 MAISLIN DRIVE, TAMPA, FL 33673
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 150
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $6000.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to hazard of electrical shock or electrocution in that the effectiveness of the insulation was not tested: a) For employees working from the bucket of the Altec bucket truck, model AA600L, serial number 0405-V1125, US DOT 981578, on or about September 9, 2015, the employer had not conducted a dielectric l test on the bucket truck at least annually. The last dielectric testing was done on June 28, 2014.
Recent events (3)
- — F (O) $6000
- — C (S) $7000
- — Z (S) $7000
1926.960 C01 I
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.960(c)(1)(i): The employer did not establish minimum approach distances (MAD) no less than the distances computed by Table V-2 for ac systems: On or about September 9, 2015 the employer did not establish a minimum approach distance (MAD) for energized work on or near 13Kv (phase to phase) power lines that was equal to or greater than the 2.13 feet required by Table V-2. Or, in the alternative: 29 CFR 1910.269(l)(3)(i): The employer did not establish minimum approach distances not less than the distances computed by Table R-3 for ac systems: a) On or about September 9, 2015 the employer did not establish a minimum approach distance (MAD) for energized work on or near 13Kv (phase to phase) power lines that was equal to or greater than the 2.13 feet required by Table R-3.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1926.960 C01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $7000.00
General-duty citation text
1926.960(c)(1)(iii): The employer did not ensure that no employee approached or took conductive objects closer to exposed energized parts than the employer's established minimum approach distance (MAD) or the distance computed by Table V-2: On or about September 9, 2015 the employer did not ensure that employees exposed to 13Kv phase to phase line voltage maintained a MAD of 2.13 feet as required by Table V-2 or that employees were insulated from the energized part by rubber insulating gloves or rubber insulating gloves and sleeves worn in accordance with standard 1926.960(c)(2) which constitutes insulation of the employee from the energized part upon which the employee is working when the employee did not have control of the part in a manner sufficient to prevent exposure to un-insulated portions of the employee's body. Likewise, energized parts were not insulated from the employee and from any other conductive object at a different potential. Or, in the alternative: 29 CFR 1910.269(l)(3)(iii): The employer did not ensure that no employee approached or took any conductive object closer to exposed energized parts than the employer's established minimum approach distance or the distance computed by Table R-3. On or about September 9, 2015 the employer did not ensure that employees exposed to 13Kv phase to phase line voltage maintained a minimum approach distance (MAD) of 2.13 feet as required by Table R-3 or that employees were insulated from the energized part by rubber insulating gloves or rubber insulating gloves and sleeves worn in accordance with standard 1910.269(l)(4) which constitutes insulation of the employee from the energized part upon which the employee is working when the employee did not have control of the part in a manner sufficient to prevent exposure to un-insulated portions of the employee's body. Likewise, energized parts were not insulated from the employee and from any other conductive object at a different potential.
Recent events (3)
- — F (S) $7000
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 237130)
LEXINGTON, KY—2026-07-09
69310 - DAVIS H ELLIOT COMPANY INC
POUGHQUAG, NY—2026-07-09
MK SHARP LLC.
KENMORE, WA—2026-07-08
WA317991980 - CASCADE TOWER & RIGGING INC
HUBBARD, TX—2026-07-07
3B DOZER SERVICE LLC
ALBANY, OR—2026-07-06
317744661 - TEXSTAR ENTERPRISES LLC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340906700.