GEISMAR, LA —
OSHA Inspection: EXCEL CONTRACTORS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EXCEL CONTRACTORS, INC. in 36187 HIGHWAY 30, GEISMAR, LA 70734 (NAICS 236220). OSHA activity number 340911015.
Where did this inspection happen?
- Establishment
- EXCEL CONTRACTORS, INC.
- Site address
- 36187 HIGHWAY 30
- City
- GEISMAR
- State
- LA
- ZIP
- 70734
- Mailing
- P.O. BOX 87410, BATON ROUGE, LA 70879
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about September 3, 2015, at the Hydrodeoxygenator (HDO) Unit, the employer did not ensure that written lock out/tag out procedures contained specific steps and techniques for locking out Valve 5208 or the same type of valve (solenoid) including but not limited to identifying its dual energy sources (electricity and air), how to isolate the electrical power source and its location, how to isolate the air source and its location, how to dissipate any residual electrical and air energy, and how to verify all energy sources are isolated to prevent the release of highly hazardous chemicals (hydrogen gas).
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.147 D06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $3500.00
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished. Before its employees commenced work on a piping system on or about September 3, 2015 at the REG Hydrodeoxygenator (HDO) Unit, the authorized employee of the contractor employer, Excel Contractors, took steps to verify that isolation and de-energization had occurred, which included the witnessing of verification steps performed by the facility owner. But the verification steps taken were insufficient to verify that a solenoid operated valve (SOV) selected and utilized by the facility owner as an energy isolation point had completely isolated the piping system from hazardous energy (hydrogen gas.)"
Recent events (3)
- — F (O) $3500
- — C (S) $0
- — Z (S) $0
More inspections at EXCEL CONTRACTORS, INC.
COMPTON, CA—2020-03-05 00:00:00
EXCEL CONTRACTORS INC
PRAIRIEVILLE, LA—2019-01-09 00:00:00
EXCEL CONTRACTORS, INC.
PRAIRIEVILLE, LA—2016-11-09 00:00:00
EXCEL CONTRACTORS, INC.
View EXCEL CONTRACTORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in LA
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
MORGAN CITY, LA—2026-07-10
G4 SERVICES LLC
PIERRE PART, LA—2026-07-08
DOLLAR GENERAL
LAKE CHARLES, LA—2026-07-01
GULF COAST FORENSIC SOLUTIONS
BATON ROUGE, LA—2026-06-26
TRAFFIC CONTROL PRODUCTS CO. OF LOUISIANA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340911015.