Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHERMAN VAN METER MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHERMAN VAN METER MASONRY, INC. in 7853 PACER DRIVE, DELAWARE, OH 43015 (NAICS 238140). OSHA activity number 340959030.

Watch Sherman VAN Meter Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Sherman VAN Meter Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7853 PACER DRIVE
City
DELAWARE
State
OH
ZIP
43015
Mailing
332 KANAWHA ROAD, LANCASTER, OH 43130
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
18
Ownership type
A

2 citations on file for this inspection.

1926.50 G

Serious Gravity 5 2 instances 13 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.50(g): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. [44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 49 FR 18295, Apr. 30, 1984; 58 FR 35084, June 30, 1993; 61 FR 5507, Feb. 13, 1996; 63 FR 33450, June 18, 1998]  a. On the sixth bunk of the scaffold where employees were working with masonry grout that contained Portland Cement, no facilities for quick drenching or flushing of the eyes and body were provided, thereby exposing the employees to a contact hazard.   b. At the mixing station where employees were mixing masonry grout that contained Portland Cement, inadequate facilities for quick drenching or flushing of the eyes and body were provided, thereby exposing the employees to a contact hazard.
Recent events (1)
  • — Z (S) $1360

1926.451 G01 VI

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).  a. On the sixth buck of the tubular frame scaffold where employees were laying block to the combined elevator/stairwell tower, the employees were not protected from falls by the use of a personal fall arrest system or guardrail system, thereby exposing the employees to a 40 foot fall hazard.
Recent events (1)
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340959030.