Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MB CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MB CONSTRUCTION, LLC in 11320 ST JOHNS ROAD, PILOT POINT, TX 76258 (NAICS 238990). OSHA activity number 340962448.

Watch MB Construction, LLC — free Get an email when a new federal OSHA severe-injury report for MB Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
11320 ST JOHNS ROAD
City
PILOT POINT
State
TX
ZIP
76258
Mailing
190 COUNTY LINE ROAD, WHITESBORO, TX 76273
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $1008.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    At a metal building construction project, employees working on the ground gathering rain gutter materials were not protected by a protective helmet while working directly below other employees who were performing the gutter installation at higher levels. The employees were exposed to being struck by objects such as tools and materials from a height of approximately 18 feet.
Recent events (2)
  • — I (S) $1008
  • — Z (S) $1440

1926.403 E

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1260.00 Reduced
29 CFR 1926.403(e): All splices and joints and free ends of conductors were not covered with insulation equivalent to that of the conductors or with an insulating device designed for the purpose:    At a metal building construction project, employees installing rain gutters using DEWALT DV268 VSR Versa-Clutch Screwdrivers with flexible cords that were not repaired using equivalent insulation exposing the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $1800

1926.405 G02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  At a metal building construction project, employees were installing rain gutters using DEWALT DV268 VSR Versa-Clutch Screwdrivers powered by extension cord that was not provided with strain relief exposing the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1260.00 Reduced
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use:    At this metal building construction project, employees operating a JCB 508c and Genie GTH-842 all-terrain material handlers were lifting and lowering employees installing rain gutters from unapproved work platforms. The platforms in use were not an approved work platforms by the manufacturer for capacity, construction, use, and fall protection. The employees were exposed to falls of approximately 18 feet to the ground below.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $1800

1926.451 G01 VII

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    At this metal building construction project, the employer did not ensure employees installing rain gutters from elevated scaffold work platforms that were not equipped with guardrails were provided with fall protection exposing them to fall hazards of approximately 18 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.602 D

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):    At a metal building construction project, employees operating a JCB 508c and Genie GTH-842 all-terrain material handlers were lifting and lowering employees installing rain gutters from unapproved work platforms. The employer did not ensure that the operators were trained prior to allowing them to operate the equipment exposing the employees to crush-by, struck-by and fall hazards from a height of approximately 18 feet.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340962448.