Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURTIN POLYMER LABORATORIES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BURTIN POLYMER LABORATORIES, INC. in 100 ENTERPRISE DRIVE, CARTERSVILLE, GA 30120 (NAICS 325998). OSHA activity number 340973023.

Watch Burtin Polymer Laboratories, INC. — free Get an email when a new federal OSHA severe-injury report for Burtin Polymer Laboratories, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 ENTERPRISE DRIVE
City
CARTERSVILLE
State
GA
ZIP
30120
Mailing
100 ENTERPRISE DRIVE, CARTERSVILLE, GA 30120
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
17
Ownership type
A

4 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    a)Body Shop - An employee used a tight fitting North full face respirator with a dual cartridge system on a volunatary basis while working with chemicals and the employer did not have him medically evaluated to ensure the respirator did not present a health hazard to the employee.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a) The Warehouse - Employees were allowed to use tight fitting full face respirators on a voluntary basis and the employer did not provide employees with the information provided in Appendix D of the respirator standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.219 E01 I

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  a) Warehouse - The Indco stand-up type mixer had a pulley drive system at approximately  6 foot, 2 inches from the floor that had no guarding to prevent accidental contact with the belt pulley system, exposing employees to amputation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a)  The facility - Employees were required to work with chemicals such as, but not limited to, Polymeric MDI and Mineral spirits, and the employer did not develop and implement a written Hazard communication program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340973023.