DUNWOODY, GA —
OSHA Inspection: GS CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GS CONSTRUCTION, INC. in 1625 MT. VERNON ROAD, DUNWOODY, GA 30338 (NAICS 237110). OSHA activity number 340980200.
Where did this inspection happen?
- Establishment
- GS CONSTRUCTION, INC.
- Site address
- 1625 MT. VERNON ROAD
- City
- DUNWOODY
- State
- GA
- ZIP
- 30338
- Mailing
- 526 LYLE CIRCLE, LAWRENCEVILLE, GA 30046
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.652 G02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $5000.00
General-duty citation text
29 CFR 1926.652(g)(2): Excavation of material to a level no greater than 2 feet (.61m) below the bottom of a shield system was allowed when there were indications while the trench was open of a possible loss of soil from behind or below the bottom of the shield: On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia: Two employees performing utility construction work were exposed to cave-in hazards when they worked inside of a section of an approximately 48-foot long, 4-foot wide, and 6-foot deep excavation that had a trench box installed approximately 5-feet from the bottom of the excavation.
Recent events (3)
- — R (O) $5000
- — C (S) $2000
- — Z (S) $2000
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $27500.00 · Current $7000.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that: On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia: Two employees performing utility construction work were exposed to cave-in hazards while working inside a section of an approximately 48-foot long, 4-foot wide, 6-foot deep excavation that did not have a protective system installed.
Recent events (3)
- — F (S) $7000
- — C (W) $27500
- — Z (W) $27500
1926.651 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees: On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia: Two employees performing water main installation work were exposed to struck-by hazards from the unprotected utility pipes running diagonally across the approximately 18-foot section of an approximately 48-foot long, 4-foot wide, and 6-foot deep excavation.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at GS CONSTRUCTION, INC.
TINLEY PARK, IL—2014-10-21 00:00:00
GS CONSTRUCTION, INC.
AGUADILLA, PR—2011-08-25 00:00:00
GS CONSTRUCTION INC
AGUADILLA, PR—2011-02-15 00:00:00
GS CONSTRUCTION INC
View GS CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
BRIDGEPORT, CT—2026-07-10
WRR, INC.
MARYSVILLE, WA—2026-07-09
WA317992011 - BDZ DEVELOPERS INC
PEORIA, IL—2026-07-08
WALTERS WATERWORKS LLC DBA MR. ROOTER PLUMBING OF PEORIA
TAMPA, FL—2026-07-08
DALLAS 1 CONSTRUCTION AND DEVELOPMENT, INC.
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340980200.