Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GS CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GS CONSTRUCTION, INC. in 1625 MT. VERNON ROAD, DUNWOODY, GA 30338 (NAICS 237110). OSHA activity number 340980200.

Watch GS Construction, INC. — free Get an email when a new federal OSHA severe-injury report for GS Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1625 MT. VERNON ROAD
City
DUNWOODY
State
GA
ZIP
30338
Mailing
526 LYLE CIRCLE, LAWRENCEVILLE, GA 30046
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.652 G02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $5000.00
29 CFR 1926.652(g)(2): Excavation of material to a level no greater than 2 feet (.61m) below the bottom of a shield system was allowed when there were indications while the trench was open of a possible loss of soil from behind or below the bottom of the shield:    On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia:    Two employees performing utility construction work were exposed to cave-in hazards when they worked inside of a section of an approximately 48-foot long, 4-foot wide, and 6-foot deep excavation that had a trench box installed approximately 5-feet from the bottom of the excavation.
Recent events (3)
  • — R (O) $5000
  • — C (S) $2000
  • — Z (S) $2000

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $27500.00 · Current $7000.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that:    On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia:    Two employees performing utility construction work were exposed to cave-in hazards while working inside a section of an approximately 48-foot long, 4-foot wide, 6-foot deep excavation that did not have a protective system installed.
Recent events (3)
  • — F (S) $7000
  • — C (W) $27500
  • — Z (W) $27500

1926.651 B04

Deleted Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees:  On or about October 7, 2015, at 1625 Mt. Vernon Road, Dunwoody, Georgia:  Two employees performing water main installation work were exposed to struck-by hazards from the unprotected utility pipes running diagonally across the approximately 18-foot section of an approximately 48-foot long, 4-foot wide, and 6-foot deep excavation.