WASHINGTON, DC —
OSHA Inspection: ALS MASONRY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALS MASONRY, LLC. in 3104 M STREET, NW, WASHINGTON, DC 20007 (NAICS 238140). OSHA activity number 340981968.
Where did this inspection happen?
- Establishment
- ALS MASONRY, LLC.
- Site address
- 3104 M STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20007
- Mailing
- 13206 HUNTINGTON LANE, WOODBRIDGE, VA 22195
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.95 A
- Issued
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) Ground Level at Base of Scaffold - A laborer was observed filling a 5 gallon bucket with Essroc Type N brick mortar which contained Portland cement and not wearing eye protection, on or about 10/13/2105. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $1360
1926.451 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a) Exterior, West Wall - Laborers were observed on a tubular welded frame scaffold work platform, 7 ft. wide and 32 ft. high, handing material to bricklayers on the second story balcony and the scaffold was not secured, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2000
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) Exterior, West Wall - Laborers were observed standing on a scaffold work platform 14 ft. above the ground and 5 cross braces were missing on the ground level sections, exposing laborers to a collapse hazard, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2000
1926.451 G04 I
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a) Exterior, West Wall - Laborers were observed standing on a tubular welded frame scaffold work platform hoisting buckets of brick mortar and the end of the platform was not provided with a guardrail, exposing the laborers to a 14 ft., fall hazard, on or about 10/13/2015. b)Exterior, West Wall - A laborer was observed kneeling down on a tubular welded frame scaffold work platform without a mid-rail, exposing the laborer to a 20 ft. 6 in. fall hazard, on or about 10/13/2015. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $2800
1926.1052 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area: a) Apartment Stairway - Masons and laborers were using a metal stairway with a three quarter inch pan and exposed to a trip and fall hazard, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1600
More inspections at ALS MASONRY, LLC.
BALTIMORE, MD—2017-07-05 00:00:00
ALS MASONRY, LLC
View ALS MASONRY, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in DC