Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BESTWAY RECYCLING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BESTWAY RECYCLING, INC. in 4005 INTERPARK DR #A, COLORADO SPRINGS, CO 80907 (NAICS 423930). OSHA activity number 340986389.

Watch Bestway Recycling, INC. — free Get an email when a new federal OSHA severe-injury report for Bestway Recycling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4005 INTERPARK DR #A
City
COLORADO SPRINGS
State
CO
ZIP
80907
Mailing
4005 INTERPARK DR #A, COLORADO SPRINGS, CO 80907
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
29
Ownership type
A

3 citations on file for this inspection.

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2550.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   (a) On or about October 14, 2015, and at times prior, Bestway Recycling, Inc. did not ensure that compressed air used for cleaning purposes was reduced to less than 30 p.s.i.. Compressed air nozzles in the plant were observed with tips that allowed air pressures of up to 108 p.s.i., exposing employees to air injection hazards.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.303 G01 I

Other-than-serious 2 instances 29 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:  (a) On or about October 14, 2015, and at times prior, Bestway Recycling, Inc. did not ensure that work space in front of electric equipment was more than 30 inches. Access to electrical panels operating at 600V or less were observed blocked by a loader bucket and waste containers.  Abatement note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 II

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  (a) On or about October 14, 2015, and at times prior, Bestway Recycling, Inc. did not ensure that flexible cords were used in continuous lengths without splice or tap. Employees were exposed to contact with electrical hazards in that a flexible cord set, charging a scissor lift battery, had been spliced approximately 2 feet from the plug.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340986389.