Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPARKMAN ELECTRIC LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPARKMAN ELECTRIC LLC in 4109 HWY 121, BEDFORD, TX 76021 (NAICS 238210). OSHA activity number 340991298.

Watch Sparkman Electric LLC — free Get an email when a new federal OSHA severe-injury report for Sparkman Electric LLC is published. One employer, no account, unsubscribe in one click.
Site address
4109 HWY 121
City
BEDFORD
State
TX
ZIP
76021
Mailing
P.O. BOX 14773, HALTOM CITY, TX 76117
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:  Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated  At a commercial construction site, an employee in an elevated aerial lift was not protected from a fall hazard of approximately 15 feet by the use of a full body harness and lanyard attached to the basket.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340991298.