OSHA Inspection: PMF, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PMF, INC. in 3438 ELDRIDGE AVE, TWIN FALLS, ID 83301 (NAICS 237110). OSHA activity number 340993179.

Watch PMF, INC. — free Get an email when a new federal OSHA severe-injury report for PMF, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PMF, INC.
Site address
3438 ELDRIDGE AVE
City
TWIN FALLS
State
ID
ZIP
83301
Mailing
P.O. BOX 1412, TWIN FALLS, ID 83301
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:    a) Jobsite: On October 9, 2015 and a tiimes prior thereto an employee did not recognize or acknowledge the hazard of working outside of the cave-in protective system that was in place.       Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  a) Jobsite: On October 9, 2015, and at times prior thereto cave in protection was not provided for employees who performed pipe connection activities outside of a concrete irrigation vault.  b) Jobsite: On October 9, 2015, and at times prior thereto cave in protection was not provided for employees while exiting the excavation using an extension ladder.    Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0