Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUILLERMO TEJADA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUILLERMO TEJADA in 1200 LEE STREET, MILTON, GA 30004 (NAICS 238130). OSHA activity number 340996263.

Watch Guillermo Tejada — free Get an email when a new federal OSHA severe-injury report for Guillermo Tejada is published. One employer, no account, unsubscribe in one click.
Establishment
GUILLERMO TEJADA
Site address
1200 LEE STREET
City
MILTON
State
GA
ZIP
30004
Mailing
460 AVALON FOREST DRIVE, LAWRENCEVILLE, GA 30044
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) Second floor top plate, new residential construction located at 1200 Lee Street, Milton, GA 30004: Employees were exposed to fall hazards of approximately 22-feet, 4-inches while installing roof trusses on the top plate with no fall protection system in place.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.701 B

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:    (a) East side, new residential construction located at 1200 Lee Street, Milton, GA 30004: Employee was exposed to impalement hazards while working on the top plate directly above unprotected rebar which was protruding 2-feet, 6-inches above the concrete foundation below.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) Temporary service box on the west side, new residential construction located at 1200 Lee Street, Milton, GA 30004: The employer failed to provide flexible cords which were free from damage. The energized internal circuits located within the protective casing of the 10-gauge cord had pulled away from the male and female ends of the cord as the strain relief was damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340996263.