Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TEXAS PRIDE UTILITIES LIMITED LIABILITY COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEXAS PRIDE UTILITIES LIMITED LIABILITY COMPANY in 4000 7TH STREET INTERSECTION THOMPSON RD, BAY CITY, TX 77414 (NAICS 541618). OSHA activity number 340998699.

Watch Texas Pride Utilities Limited Liability Company — free Get an email when a new federal OSHA severe-injury report for Texas Pride Utilities Limited Liability Company is published. One employer, no account, unsubscribe in one click.
Site address
4000 7TH STREET INTERSECTION THOMPSON RD
City
BAY CITY
State
TX
ZIP
77414
Mailing
28610 BENDERWOOD, SPRING, TX 77386
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541618
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:(a)(    At this job site, employees entered and worked in an excavation greater than 4 ft in depth without a ladder or other safe means of egress.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    At this job site, the spoil pile was placed at the east edge of the excavation.  Employees were exposed to being struck or crushed by excavated dirt.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i)    At this job site, an employee entered and worked in an unprotected excavation greater than five feet deep without a protective system.  The employee was exposed  to cave-in hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340998699.