POWDER SPRINGS, GA —
OSHA Inspection: JUAN PEREZ TAPIA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUAN PEREZ TAPIA in 4331 BRYSON COURT, POWDER SPRINGS, GA 30127 (NAICS 238140). OSHA activity number 341001949.
Where did this inspection happen?
- Establishment
- JUAN PEREZ TAPIA
- Site address
- 4331 BRYSON COURT
- City
- POWDER SPRINGS
- State
- GA
- ZIP
- 30127
- Mailing
- 5169 ELLEN STREET, FOREST PARK, GA 30297
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: (a) Front side, new residential construction located at 4331 Bryson Court, Powder Springs, GA 30127: Employees were exposed to fall hazards while engaged in masonry work on a tubular welded scaffold platform which was not fully planked. Employees were exposed to falls of approximately 12-feet, 1-inch to the lower level.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.451 G01
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: (a) Front side, new residential construction located at 4331 Bryson Court, Powder Springs, GA 30127: Employees were exposed to fall hazards of approximately 12-feet, 1-inch to the lower level while installing bricks on a tubular welded scaffold platform in which a fall protection system was not provided.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.403 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) Front side, new residential construction located at 4331 Bryson Court, Powder Springs, GA 30127: The employer failed to inspect all of the electrical cords prior to the start of the work shift. A 50 ft. flexible cord used to power a Makita (Model 5007F) 7-1/4-inch Circular Saw had a torn outer casing, missing strain relief, and a missing ground pin and was not removed from service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source