OSHA Inspection: DOME ASSEMBLY CONTRACTORS, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DOME ASSEMBLY CONTRACTORS, LLC in 65 COLUMBIA RD, MORRISTOWN, NJ 07960 (NAICS 561790). OSHA activity number 341004620.

Watch Dome Assembly Contractors, LLC — free Get an email when a new federal OSHA severe-injury report for Dome Assembly Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
65 COLUMBIA RD
City
MORRISTOWN
State
NJ
ZIP
07960
Mailing
26 CEDAR HILL AVE., BELLEVILLE, NJ 07109
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
1
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  The employer did not provide abatement certification for inspection number 1100462 as indicated below:  1.      Citation 1 Item 2a pertaining to 29 CFR 1910.1200(e)(1) which was issued on 03/21/2016.  Abatement for this item was due on 06/20/2016. 2.      Citation 1 Item 2b pertaining to 29 CFR 1910.1200(h)(1) which was issued on 03/21/2016.  Abatement for this item was due on 06/20/2016.  Employer received citations on 04/29/2016.  Violation occurred on or about 10/15/2015.
Recent events (1)
  • — Z (O) $400

1910.1000 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances C730

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of carbon monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 parts per million (ppm):    a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ    Three subcontractor employees who were cleaning the Men's locker room were exposed to carbon monoxide (CO) during a 30 minute occupational exposure.  One employee had a mean calculated exposure of 1668.3 parts per million (ppm) CO (SAE= 0.143).  The present carboxyhemoglobin (COHb) in the employee's blood reached a calculated peak level of 38.9%.  Atmospheric pressure, height, weight, activity level, tobacco smoking behavior and other factors were taken into account.  The 8-hour Time Weighted Average (TWA) exposure was 104.3ppm CO (SAE 0.141) which is 2.09 times the OSHA Permissible Exposure Limit (PEL) of 50 ppm CO.      Conditions occurred on or about 10/15/2015.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.1000 E

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances C730

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ  Three subcontractor employees who were cleaning the Men's locker room were exposed to carbon monoxide (CO) during a 30 minute occupational exposure.  One employee had a mean calculated exposure of 1668.3 parts per million (ppm) CO (SAE= 0.143).  The present carboxyhemoglobin (COHb) in the employee's blood reached a calculated peak level of 38.9%.  Atmospheric pressure, height, weight, activity level, tobacco smoking behavior and other factors were taken into account.  The 8-hour Time Weighted Average (TWA) exposure was 104.3ppm CO (SAE 0.141) which is 2.09 times the OSHA Permissible Exposure Limit (PEL) of 50 ppm CO.  Conditions occurred on or about 10/15/2015.  Effective means of abatement include, but are not limited to:     a) Limit the use of gasoline power washer to outdoor activities,     b) Use an electric power washer for all indoor cleaning tasks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances C730

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a)  Center Court of Morristown, 65 Columbia Rd. Morristown, NJ    The employer did not develop and implement a written hazard communication program for subcontractor employees exposed to hazardous chemicals including, but not limited to, carbon monoxide as a product of combustion while operating a gasoline powered power washer indoors.  Three such employees were admitted to the hospital due to an overexposure to carbon monoxide.    Conditions occurred on or about 10/15/2105.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.1200 H01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances C730

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ    The employer did not provided effective information and training to subcontractor employees who were operating a gasoline powered power washer indoors and exposed to carbon monoxide.   Three such employees were admitted to the hospital after an overexposure to carbon monoxide.    Conditions occurred on or about 10/15/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341004620.