TEMPLE, PA —
OSHA Inspection: METAL SERVICE OF TEMPLE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of METAL SERVICE OF TEMPLE, INC. in 4700 NORTH 5TH STREET HIGHWAY, TEMPLE, PA 19560 (NAICS 332322). OSHA activity number 341005155.
Where did this inspection happen?
- Establishment
- METAL SERVICE OF TEMPLE, INC.
- Site address
- 4700 NORTH 5TH STREET HIGHWAY
- City
- TEMPLE
- State
- PA
- ZIP
- 19560
- Mailing
- 4700 NORTH 5TH STREET HIGHWAY, TEMPLE, PA 19560
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Metal Service of Temple, Inc., 4700 North 5th Street Highway, Temple, Pennsylvania - Employees performed servicing and maintenance activities, such as replacing parts and tool and die changes, on machinery and equipment, including, but not limited to, the Murata Wiedemann Centrum 2500 CNC turret punch, the 90-ton Cincinnati hydraulic press brake, the Chicago Dreis & Krump mechanical press brake, and the Amada RG-50 hydraulic press brake, and the employer did not develop and implement an energy control program, consisting of machine specific energy control procedures, group lockout/tagout, testing and positioning procedures, periodic inspections, and employee training, exposing employees to hazards, including but not limited to, getting caught-in and struck-by moving machine parts, on or about October 22, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Metal Service of Temple, Inc., 4700 North 5th Street Highway, Temple, Pennsylvania - Employees performed servicing and maintenance activities, such as replacing parts and tool and die changes, on machinery and equipment, including, but not limited to, the Murata Wiedemann Centrum 2500 CNC turret punch, the 90-ton Cincinnati hydraulic press brake, the Chicago Dreis & Krump mechanical press brake, and the Amada RG-50 hydraulic press brake, and the employer did not develop, document, and implement machine specific energy control procedures, exposing employees to hazards, including but not limited to, getting caught-in and struck-by moving machine parts, on or about October 22, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from hazards created by a moving table: (a) Shop - One of the safety mats for protecting the working envelope of the moving table on the Murata Wiedemann Centrum 2500 CNC turret punch, which would stop the Murata Wiedemann Centrum 2500 CNC turret punch if an employee stepped onto the mat, no longer worked. The employer removed this mat but had not yet installed the new replacement safety mat or implemented another equivalent protective method, and employees continued to run the turret, exposing employees to the hazard of getting struck-by the moving table, on or about October 22, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: (a) Shop - Employees used a foot pedal to operate the Cincinnati 90-ton hydraulic press brake, serial number 42893, to bend work pieces, some of which required the employees to get to within 4 inches of the point of operation, and the press brake did not have point of operation guarding, exposing employees to the hazard of getting caught in the point of operation, on or about October 12, 2015. (b) Shop - Employees bent some long work pieces on the Cincinnati 90-ton hydraulic press brake, serial number 42893, that required the press operator and a helper to hold. The press had one foot pedal, which the press operator used to cycle the press, but the helper had no foot pedal and no other protection from the point of operation for this work, exposing the helper to the hazard of getting caught in the point of operation, on or about October 12, 2015. (c) Shop - Employees used a foot pedal to operate the Chicago Dreis & Krump 90-ton mechanical press brake, serial number L2804, to flatten hems on pieces of expanded metal, and the press brake did not have point of operation guarding, exposing employees to the hazard of getting caught in the point of operation, on or about October 12, 2015. (d) Shop - Employees used a foot pedal to operate the Amada RG-50 hydraulic press brake, serial number 5058987, to bend work pieces, some of which required the employees to get to within 4 inches of the point of operation, and the press brake did not have point of operation guarding, exposing employees to the hazard of getting caught in the point of operation, on or about October 22, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
More inspections in this industry (NAICS 332322)
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
KISSIMMEE, FL—2026-07-14
JELD-WEN
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341005155.