OSHA Inspection: CHARLES P. & CAROL V. MCBRIDE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHARLES P. & CAROL V. MCBRIDE in 1266 KENNESTONE CIRCLE SUITE 105, MARIETTA, GA 30066 (NAICS 323120). OSHA activity number 341015840.

Watch Charles P. & Carol V. Mcbride — free Get an email when a new federal OSHA severe-injury report for Charles P. & Carol V. Mcbride is published. One employer, no account, unsubscribe in one click.
Site address
1266 KENNESTONE CIRCLE SUITE 105
City
MARIETTA
State
GA
ZIP
30066
Mailing
1266 KENNESTONE CIRCLE SUITE 105, MARIETTA, GA 30066
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323120
Employees
27
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2800.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) In the production area, the employer did not establish a lockout/tag out program consisting of energy control procedures, employee training, and periodic inspections, exposing the employees to electrical and amputation hazards. The employees were required to service and maintain equipment such as, but not limited to, printing presses, flat bed cutters, die cutters, and folders.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4900

1910.303 G01

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1500.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) In the printing press room, on the feeder side of Printing Press CD74, sufficient access and clearance was not provided for electrical service panels, exposing the employees to electrical and trip hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1700.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) In the printing press room, on the feeder side of Printing Press CD74, unused openings in electrical boxes were not effectively closed, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3500