Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIXIANA STEEL COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DIXIANA STEEL COMPANY in 1339 LANEY WALKER BLVD., AUGUSTA, GA 30901 (NAICS 238120). OSHA activity number 341021574.

Watch Dixiana Steel Company — free Get an email when a new federal OSHA severe-injury report for Dixiana Steel Company is published. One employer, no account, unsubscribe in one click.
Site address
1339 LANEY WALKER BLVD.
City
AUGUSTA
State
GA
ZIP
30901
Mailing
1544 PINE RIDGE DR, WEST COLUMBIA, SC 29169
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
50
Ownership type
A

2 citations on file for this inspection.

1926.760 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5000.00 · Current $5000.00
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  On or about October 21, 2015 at 1339 Laney Walker Blvd., Augusta, GA., an employee working at the ridge cutting the tails off the joist was not protected from falling between 33 feet, 8 inches and 22 feet, 8 inches to the lower level.
Recent events (3)
  • — A (S) $5000
  • — I (S) $3400
  • — Z (S) $5000

1926.761 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $3500.00
29 CFR 1926.761(b): The employer did not institute a training program and ensure all employees exposed to fall hazards; recognize and identify fall hazards in the work area, use and operate guardrails systems (including perimeter safety cables systems) , personal fall arrest systems, positioning devices systems, fall restraint systems, safety nets, and other fall protection to be used; the correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection system to be used, the procedures to be followed to prevent falls to the lower levels and through holes and openings in the walking /working surfaces and walls; and the fall protection requirements of this subpart.   On or about October 21 2015 at 1339 Laney Walker Blvd., Augusta, GA., the employer failed to institute a training program where employee recognized and identified fall hazards in the workplace, use and operate personal fall arrest systems when exposed to fall hazards of 33'-8" to 22'-8" to the lower level.
Recent events (3)
  • — A (S) $3500
  • — I (S) $2400
  • — Z (S) $3500

View DIXIANA STEEL COMPANY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341021574.