Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CELLU TISSUE - CITYFOREST, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CELLU TISSUE - CITYFOREST, LLC in 1215 EAST WORDEN AVE, LADYSMITH, WI 54848 (NAICS 322121). OSHA activity number 341025112.

Watch Cellu Tissue - Cityforest, LLC — free Get an email when a new federal OSHA severe-injury report for Cellu Tissue - Cityforest, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1215 EAST WORDEN AVE
City
LADYSMITH
State
WI
ZIP
54848
Mailing
1215 EAST WORDEN AVE, LADYSMITH, WI 54848
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
81
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5500.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:     (a)  Wet lap machine; On or about October 23, 2015, a means of fall protection was not provided for open sides on work surfaces elevated greater than 4 feet above the lower level.
Recent events (3)
  • — R (S) $5500
  • — C (S) $7000
  • — Z (S) $7000

1910.261 B01

Serious Gravity 10 3 instances 20 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.261(b)(1): The employer did not ensure that the main power disconnect switch or valve, or both, controlling its source of power or flow of material, was locked out or blocked off with padlock, blank flange, or similar device before conducting any maintenance, inspection, cleaning, adjusting, or servicing of equipment (electrical, mechanical, or other) that required entrance into or close contact with the machinery or equipment:    (a) In the facility; During the time period from October 23, 2015 through October 27, 2015 equipment was not deenergized and locked out prior to performing cleaning, clearing jams and servicing on equipment including, but not limited to the following:   i.  cleaning and clearing jams on the wet lap machine;  ii. servicing, cleaning and clearing jams on the forward cleaners; and  iii. servicing and clearing jams on the course screen in the deinking process.
Recent events (3)
  • — R (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.261 B01

Repeat Gravity 10 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $70000.00 · Current $60000.00 Reduced
29 CFR 1910.261(b)(1): The employer did not ensure that the main power disconnect switch or valve, or both, controlling its source of power or flow of material, was locked out or blocked off with padlock, blank flange, or similar device before conducting any maintenance, inspection, cleaning, adjusting, or servicing of equipment (electrical, mechanical, or other) that required entrance into or close contact with the machinery or equipment:    (a) In the facility; Equipment was not deenergized and locked out prior to performing cleaning, clearing jams and servicing on equipment including, but not limited to the following:   i.  cleaning and clearing jams on the disperger in the deinking process and  ii. cleaning and clearing jams on the dewatering conveyor.
Recent events (3)
  • — R (R) $60000
  • — C (W) $70000
  • — Z (W) $70000

1910.147 C06 I

Repeat Gravity 10 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $35000.00 · Current $60000.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a) Throughout the facility; The employer was not performing energy control procedure audits at least annually to ensure the accuracy of the lockout tagout procedure to include energy isolation and a review with employees and the person performing the audit.    Cellu Tissue-CityForest, LLC dba Clearwater Paper-Ladysmith was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(6)(i), which was contained in OSHA inspection number 279525, citation number 1, item number 1A and was affirmed as a final order on May 08, 2012, with respect to a workplace located at 1215 East Worden Avenue, Ladysmith, WI 54848.
Recent events (3)
  • — R (R) $60000
  • — C (R) $35000
  • — Z (R) $35000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341025112.