Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSUE VILLALOBOS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSUE VILLALOBOS in LOT 44 CHIPPEWA DR., SHILOH, IL 62269 (NAICS 238160). OSHA activity number 341039832.

Watch Josue Villalobos — free Get an email when a new federal OSHA severe-injury report for Josue Villalobos is published. One employer, no account, unsubscribe in one click.
Establishment
JOSUE VILLALOBOS
Site address
LOT 44 CHIPPEWA DR.
City
SHILOH
State
IL
ZIP
62269
Mailing
580 MCBRIDE AVE., DUPO, IL 62239
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    Eye protective equipment was not used when employees were exposed to eye injury while using pneumatic nail guns.
Recent events (3)
  • — A (S) $2400
  • — I (S) $1680
  • — Z (S) $2400

1926.152 D04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.152(d)(4): At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids:    The employer did not ensure that a portable fire extinguisher was available to employees who were carrying a 5 gallon gas can in the vehicle. The gasoline was being used to fill the air compressor.
Recent events (3)
  • — A (S) $2000
  • — I (S) $1400
  • — Z (S) $2000

1926.307 D01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs  (m) and  (o) of this section:    A gasoline-powered air compressor was being used for roofing activities at a residential house and the pulley, belt and parts were not guarded.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1960
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     Employees were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or any other approved mean. Employees were in the process of installing a new roof on an 10 in 12 pitch roof. While working on the roof employees was exposed to falls of approximately 11.3 feet to a lower level.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    A 28-ft extension ladder was not being used for the purpose for which it was designed. The base section and fly section of the ladder were separated and the fly section was used to access the roof of a residential house.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B16

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:    A 28-ft extension ladder had structural defects, such as but not limited to, damaged side rails, and was being used to access the roof of a residential house. The ladder was not marked in a manner that readily identified it as defective, tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1960
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341039832.