ANNISTON, AL —
OSHA Inspection: CARLSON COMPOSITES (AL) LP
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CARLSON COMPOSITES (AL) LP in 1861 ELECTRONICS DRIVE, ANNISTON, AL 36207 (NAICS 326140). OSHA activity number 341040319.
Where did this inspection happen?
- Establishment
- CARLSON COMPOSITES (AL) LP
- Site address
- 1861 ELECTRONICS DRIVE
- City
- ANNISTON
- State
- AL
- ZIP
- 36207
- Mailing
- 1861 ELECTRONICS DRIVE, ANNISTON, AL 36207
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326140
- Employees
- 53
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Penalty
- Initial $2295.00 · Current $1377.00 Reduced
1750
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) On or about 11/4/15 - Gelcoat area, containers that previously held Norox MEKP-9 and Norox MEKP 925-H had accumulated in the area. (b) On or about 11/4/15 -- Gelcoat area, empty 55-gallon drums that previously held resin had accumulated in the area.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.106 E06 I
- Issued
- Abate by
- Penalty
- Initial $4590.00 · Current $2754.00 Reduced
00402280
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: (a) On or about 11/4/15 - Resin Transfer Molding area, waste from the GlasCraft resin dispensing system was placed in an open top drum.
Recent events (2)
- — I (S) $2754
- — Z (S) $4590
1910.107 E02
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: (a) On or about 11/4/15 - Gel coat area, approximately 35 drums of the polyester resin were observed in the area and exceeded the daily use of the flammable resin.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 11/4/15 - Facility, a written hazard communication program had not been developed for employees handling resins, peroxides and solvents used in the manufacturing of polystyrene parts.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1750
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) On or about 11/4/15 - Gelcoat area, the container of catalyst used on the Glas-Craft mixing system was not labeled as to hazard or content. (b) On or about 11/4/15 - RTM area, the container of catalyst used on the Glas-Craft RTM injection system was not labeled as to hazard or content. (c) On or about 11/4/15 - Lamination area, the container of catalyst used on the Graco FRP system was not labeled as to hazard or content. (d) On or about 11/4/15 - Mold preparation area, secondary containers of mold release and mold stripper were not labeled to identify the hazard of the materials.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.120 Q01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
17502280
General-duty citation text
29 CFR 1910.120(q)(1): The employer, who would evacuate employees from the danger area when an emergency occurred and would not permit any employees to assist in handling the emergency, did not provide an emergency action plan in accordance with 1910.38: (a) On or about 11/4/15 - at the Facility, a written emergency action plan had not been developed for the site.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326140)
BOLINGBROOK, IL—2026-06-09
CLARK FOAM PRODUCTS CORPORATION
SWEDESBORO, NJ—2026-04-30
DIVERSIFIED FOAM PRODUCTS
VISALIA, CA—2026-04-14
PREGIS INNOVATIVE PACKAGING LLC
CORONA, CA—2026-03-27
DART CONTAINER CORPORATION
EDISON, NJ—2026-03-26
CRYOPAK, INC.
More inspections in AL
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
LOXLEY, AL—2026-07-16
CARLOS CHE
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
BIRMINGHAM, AL—2026-07-14
SCHOLAR CRAFT PRODUCTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341040319.