Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAGLE MASONRY CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAGLE MASONRY CORPORATION in 201 EDGEWATER STREET SANDY HOOK PILOTS ASSOCIATION, STATEN ISLAND, NY 10305 (NAICS 238140). OSHA activity number 341045979.

Watch Eagle Masonry Corporation — free Get an email when a new federal OSHA severe-injury report for Eagle Masonry Corporation is published. One employer, no account, unsubscribe in one click.
Site address
201 EDGEWATER STREET SANDY HOOK PILOTS ASSOCIATION
City
STATEN ISLAND
State
NY
ZIP
10305
Mailing
1535 RICHMOND AVE, STATEN ISLAND, NY 10314
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.     a. 201 Edgewater Street, Staten Island, NY - Sandy Hook Pilots Association Construction Site    Employees engaged in masonry activities were not protected from potential eye or face injury.  An employee was observed cutting block with a Husqvarna K760 gasoline powered cut-off saw without the use of eye or face protection.    Violation observed on or about November 9, 2015
Recent events (3)
  • — F (S) $960
  • — C (S) $1600
  • — Z (S) $1600

1926.451 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide:     a. 201 Edgewater Street, Staten Island, NY - Sandy Hook Pilot's Association Construction Site    Employees engaged in masonry activities of a block wall used a welded tubular frame scaffold with spaces greater than 1 inch between planks.     Violation observed on or about November 9, 2015
Recent events (3)
  • — F (S) $720
  • — C (S) $1200
  • — Z (S) $1200

1926.451 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:    a. 201 Edgewater Street, Staten Island, NY - Sandy Hook Pilot's Association Construction Site    The employer did not ensure that all working levels of a welded tubular frame scaffold were fully braced.  Employees engaged in masonry activities used a frame scaffold that had cross bracing installed only on one side.     Violation observed on or about November 9, 2015
Recent events (3)
  • — F (S) $1440
  • — C (S) $2400
  • — Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341045979.