Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CALLOWAY CONCRETE PUMPING LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of CALLOWAY CONCRETE PUMPING LLC in 5900 AUSTRALIAN AVENUE, WEST PALM BEACH, FL 33407 (NAICS 238140). OSHA activity number 341100980.

Watch Calloway Concrete Pumping LLC — free Get an email when a new federal OSHA severe-injury report for Calloway Concrete Pumping LLC is published. One employer, no account, unsubscribe in one click.
Site address
5900 AUSTRALIAN AVENUE
City
WEST PALM BEACH
State
FL
ZIP
33407
Mailing
10111 SANDY RUN ROAD, JUPITER, FL 33478
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:  On or about 12/07/2015, at the above addressed worksite, employees using a chipping hammer to break concrete did not have eye protection exposing them to the potential of an eye injury.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.701 B

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement:  On or about 12/07/2015, at the above addressed worksite, employees demolishing a concrete ramp were exposed to a laceration hazard while working adjacent to uncapped rebar rods.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:  On or about 12/07/2015, at the above addressed worksite, the employer did not maintain a hazard communication program for employees using gasoline to power a demolition saw.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341100980.