Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JC CONTRACTOR, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JC CONTRACTOR, LLC in 9977 LORALINDA DR., CINCINNATI, OH 45251 (NAICS 238160). OSHA activity number 341103919.

Watch JC Contractor, LLC — free Get an email when a new federal OSHA severe-injury report for JC Contractor, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JC CONTRACTOR, LLC
Site address
9977 LORALINDA DR.
City
CINCINNATI
State
OH
ZIP
45251
Mailing
4205 TRADEWIND CT, ENGLEWOOD, OH 45322
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  Located on the east side of a residential roof structure, employees were observed performing roofing work on a low pitch roof not utilizing any fall protection system. Potential fall height was measured in excess of 9'-7" with a roof pitch of 4/12.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341103919.