Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OLD WORLD CABINET, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of OLD WORLD CABINET, INC in 322 MAIN ST, LINWOOD, KS 66052 (NAICS 337110). OSHA activity number 341107506.

Watch OLD World Cabinet, INC — free Get an email when a new federal OSHA severe-injury report for OLD World Cabinet, INC is published. One employer, no account, unsubscribe in one click.
Site address
322 MAIN ST
City
LINWOOD
State
KS
ZIP
66052
Mailing
PO BOX 140, LINWOOD, KS 66052
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
7
Ownership type
A

11 citations on file for this inspection.

1910.134 K06

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $320.00 Reduced

Hazardous substances 81108111

29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  Employees engaged in woodworking activities were exposed to respiratory hazards in that the employer allowed voluntary use of dust masks without providing Appendix D of 29 CFR 1910.134 to employees.
Recent events (2)
  • — I (S) $320
  • — Z (S) $1600

1910.213 B03

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $240.00 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  Employees engaged in woodworking activities were exposed to amputation hazards in that the table mounted router could restart after the return of a loss of power.
Recent events (2)
  • — I (S) $240
  • — Z (S) $1200

1910.213 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $320.00 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Employees engaged in woodworking activities were exposed to amputation hazards in that the circular handfed Sawstop ripsaws were not guarded.
Recent events (2)
  • — I (S) $320
  • — Z (S) $1600

1910.213 C03

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  Employees engaged in woodworking activities were exposed to struck-by hazards in that the Sawstop hand-fed ripsaws did not have kickback fingers or dogs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $320.00 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with stock being cut:  Employees engaged in woodworking activities were exposed to amputation hazards in that the circular handfed Delta Shopmaster radial saw was not guarded.
Recent events (2)
  • — I (S) $320
  • — Z (S) $1600

1910.305 A02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $480.00 Reduced
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:  Employees operating a Makita hand held belt sanders were exposed to electrical shock and fire hazards in that the extension cord connected to the belt sander was connected to an additional extension cord.
Recent events (2)
  • — I (S) $480
  • — Z (S) $2400

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Employees engaged in woodworking activities were exposed to electrical shock and fire hazards in that the relocatable power taps were permanently secured to the shop walls, used in place of fixed wiring and connected to extension cords.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $240.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Employees engaged in woodworking activities were exposed to electrical shock and fire hazards in that the table mounted router and electrical breaker panels had openings that were not effectively closed.  Instances include:  1 - Electrical breaker panels had multiple unused openings   2 - Electrical knockout on the disconnect for the table mounted router near the table saw was not closed
Recent events (2)
  • — I (S) $240
  • — Z (S) $1200

1910.305 B02 I

Serious Gravity 1 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $240.00 Reduced
29 CFR 1910.305(b)(2)(i):  All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear:  Employees were exposed to electrical shock hazards in that the electrical junction box and outlets were not covered.  Instances included:  1 - Electrical 4 inch by 4 inch junction box located in the west end of the shop   2 - Outlet in break area between offices and shop area  3 - Outlet above workbench on west wall of east end shop area
Recent events (2)
  • — I (S) $240
  • — Z (S) $1200

1910.303 F02

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $320.00 Reduced
29 CFR 1910.303(f)(2):  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Employees engaged in woodworking activities were exposed to amputation and electrical shock hazards in that the electrical panels with branch circuits were not legibly marked to indicate its purpose.
Recent events (2)
  • — I (S) $320
  • — Z (S) $1600

1910.334 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $240.00 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  Employees engaged in belt sanding activities were exposed to electrical shock hazards in that portable cord and plug connected equipment and flexible cord sets were not visually inspected as required.
Recent events (2)
  • — I (S) $240
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341107506.