DE WITT, AR —
OSHA Inspection: MENARD MANUFACTURING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MENARD MANUFACTURING INC. in 6401 HWY 152, DE WITT, AR 72042 (NAICS 332312). OSHA activity number 341126126.
Where did this inspection happen?
- Establishment
- MENARD MANUFACTURING INC.
- Site address
- 6401 HWY 152
- City
- DE WITT
- State
- AR
- ZIP
- 72042
- Mailing
- 6401 HWY 152, DE WITT, AR 72042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 25
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: On or about December 15, 2015, in the Specialty Shop, employee on an elevated pallet platform attached to the forks of a powered industrial truck, was not donned in fall protection and was not protected from falling while grinding and welding on a vac tank. This condition exposed employee to falls of greater than 4 feet.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.110 H12
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.110(h)(12): Conspicuous signs prohibiting smoking were not posted within sight of customers served at LP gas dispensing areas: On or about December 15, 2015, and times prior to, a "No Smoking" sign was not posted on or near the (a) 500 gallon propane tank staged outside in the LP Bottle Fill area. (b) 1000 gallon propane tank located outside for the Hot Water Washer area. This conditions exposed employees to a fire hazard.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about December 15, 2015, and times prior to, the following forklifts were not outfitted with a seat belt: (a) The #5 Daewoo forklift located in the Maintenance Shop that was used for picking up and unloading freight. (b) The #4 Toyota forklift located in the Specialty Shop that was used for transporting parts. This condition exposed employees to the hazard of being thrown, ejected and crushed in the event of a tip-over. (c) Employees are not provided with a face shield and apron when refueling LP cylinders for forklifts. This condition exposed employees to contact with the fuel.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 M05 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not netralized, power was not shut off, and brakes set: On or about December 15, 2015, in the Specialty Shop, the forks on the Toyota #4 powered industrial forklift were left elevated while the forklift was unattended. This condition exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about December 15, 2015, and times prior to, the unused portion of the cutting blade was not guarded on the (a) Hyd-Mech horizontal band saw located in the back west side of the saw area. (b) Hyd-Mech horizontal band saw located in the back east side of the saw area. These conditions exposed employees to contact with the cutting blade. (c) The rotating chuck on the Monarch lathe, s/n 22030, located in the Machine Shop, was not guarded. This condition exposed employees to contact with rotating parts.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about December 15, 2015, and times prior to, Fabrication area, an inner guard was not provided over the pulley on the motor drive to the 8 ft. diameter shop built fan. This condition exposed employees to contact with nip points.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.219 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about December 15, 2015, and times prior to, Fabrication area, an inner guard was not provided over the double belts on motor drive to the 8 ft. diameter shop built fan. This condition exposed employees to contact with nip points.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(a): The conductors and/or equipment required or permitted by this subpart were not approved: On or about December 15, 2015, and times prior to, in the Shear Department, a non-metallic sheathed cable (Romex cable) ran from the electrical box on the shear machine and connected to the metal outlet box that supplied power to the microwave. This condition exposed employees to electrical shock and/or fire.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about December 15, 2015, and times prior to, in the Shear Department, the metal outlet box that supplied power to the microwave was not fixed. The outlet box was listed to be installed within a wall as a permanent fixture. This condition exposed employees to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about December 15, 2015, and times prior to, in the Shear Department, the ground pin was missing from the cord plug of the flexible cord powering the microwave. This condition exposed employees to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about December 15, 2015, in the Shear Department, the openings on the 110 volt metal outlet box that supplied power to the microwave were not covered. This condition exposed employees to an electrical shock hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: On or about December 15, 2015, and times prior to, the 500 gallon propane tank staged outside in the LP Bottle Fill area, and the 1000 gallon propane tank located in the Hot Water Washer area were not labeled to indicate their contents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in AR
SILOAM SPRINGS, AR—2026-07-15
CR CRAWFORD CONSTRUCTION LLC
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
BRINKLEY, AR—2026-07-14
ROGER WILKISON FARMS PARTNERSHIP
SEARCY, AR—2026-07-14
MASTER?S PLASTERING & MORE INC
LITTLE ROCK, AR—2026-07-09
NABHOLZ CONSTRUCTION CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341126126.