Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CESAR JULIAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CESAR JULIAN in 1910 JESSE JEWEL PARKWAY, GAINESVILLE, GA 30501 (NAICS 238160). OSHA activity number 341127454.

Watch Cesar Julian — free Get an email when a new federal OSHA severe-injury report for Cesar Julian is published. One employer, no account, unsubscribe in one click.
Establishment
CESAR JULIAN
Site address
1910 JESSE JEWEL PARKWAY
City
GAINESVILLE
State
GA
ZIP
30501
Mailing
538 HUNTINGTON PLACE, ROSWELL, GA 30076
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about December 15, 2015:  a) An employee working on roofing system was exposed to fall hazards of approximately 10.6 feet when the employer failed to ensure that the employee was properly protected form the fall by the use of fall protection measures.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about December 15, 2015:  a) Employees were exposed to fall hazards of approximately 10.6 feet when the employer failed to ensure the extension ladder being used to gain access to the upper landing had its rails extending at least three feet above the upper landing surface.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.1053 B16

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  On or about December 15, 2015:  a) Employees were exposed to fall hazards when the ladder they were using had damage to the rungs on the ladder.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341127454.