CROYDON, PA —
OSHA Inspection: STANDARD FUSEE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STANDARD FUSEE CORPORATION in 2975 STATE ROAD, CROYDON, PA 19021 (NAICS 325998). OSHA activity number 341135820.
Where did this inspection happen?
- Establishment
- STANDARD FUSEE CORPORATION
- Site address
- 2975 STATE ROAD
- City
- CROYDON
- State
- PA
- ZIP
- 19021
- Mailing
- 28320 ST. MICHAELS ROAD, EASTON, MD 21601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 E01
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.119(e)(1): The employer did not perform an initial process hazard analysis (hazard evaluation) on processes covered by 29 CFR 1910.119: a) Standard Fusee Corporation, - On or about December 16, 2015, the employer operated a Process Safety Management (PSM) covered explosive pyrotechnic manufacturing process, without a Process Hazard Analysis (PHA) completed for the process that included these operations.
Recent events (3)
- — F (S) $3000
- — C (S) $3060
- — Z (S) $3060
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $3825.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: a) Standard Fusee Corporation, Charging Room - On or about February 12, 2016, the sprocket wheels and chain of the charging / loading machine were not guarded to prevent injuries to employees.
Recent events (3)
- — F (S) $3000
- — C (S) $3825
- — Z (S) $3825
1910.119 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.119(f)(3): The employer did not annually certify that operating procedures were current and accurate. a) Standard Fusee Corporation, - On or about December 16, 2015, the employer did not certify that their SOP-01BR Emergency Evacuation Plan was current and accurate since October 30, 2008. b) Standard Fusee Corporation, - On or about December 16, 2015, the employer did not certify that their SOP-08BR restriction on Smoking & Open Lights was current and accurate since October 30, 2008. c) Standard Fusee Corporation, - On or about December 16, 2015, the employer did not certify that their SOP-39BR Hazardous Communication Program was current and accurate since October 30, 2008. d) Standard Fusee Corporation, - On or about December 16, 2015, the employer did not certify that their SOP-110BR Orange Smoke Signal Assembly was current and accurate since October 30, 2008.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.119 F04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel: a) Standard Fusee Corporation, Charging Room - On or about December 16, 2015, the employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout and control over entrance into a facility by maintenance, or other support personnel.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Standard Fusee Corporation, Charging Room - On or about December 16, 2015, the employer did not conduct a periodic inspection of their energy control procedure since on October, 2008 to ensure that the procedure and the requirement of the OSHA standards were being followed.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Standard Fusee Corporation, - On or about February 12, 2016, a Romex brand nonmetallic-sheathed cable being used to supply power to a DC controller and a Rockwell brand floor standing drill press, was not installed in accordance with instructions included in the listing or labeling. ABTEMENT NOTE: Among other methods, one feasible and acceptable means of abatement is to follow the instructions and guidelines of Article 334 of ANSI/NFPA 70, "National Electrical Code" and the Underwriters Laboratory White Book information.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: a) Standard Fusee Corporation, - On or about February 12, 2016, did not ensure that each container of their Wick Paint primer mixture was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii). b) Standard Fusee Corporation, - On or about February 12, 2016, did not ensure that each container of their Button Paint mixture was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii).
Recent events (3)
- — F (O) $0
- — C (S) $2295
- — Z (S) $2295
1910.1200 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(2): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included the required headings and information in 29 CFR 1910.1200(g)(2)(i) through 29 CFR 1910.1200(g)(2)(xii) a) Standard Fusee Corporation, - On or about February 12, 2016, the employer who manufactures their Wick Paint primer chemical on site did not ensure that a Safety Data Sheet was developed and used with all the required information for that mixture as required. b) Standard Fusee Corporation, - On or about February 12, 2016, the employer who manufactures their Button Paint mixture chemical on site did not ensure that a Safety Data Sheet was developed and used with all the required information for that mixture as required.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at STANDARD FUSEE CORPORATION
SOUTH BELOIT, IL—1997-01-30 00:00:00
STANDARD FUSEE CORPORATION
View STANDARD FUSEE CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 325998)
WILLOWS, CA—2026-07-15
HYERA INC
SAN ANTONIO, TX—2026-07-15
BLUE LINE CORPORATION
CHARLOTTE, TX—2026-07-07
CLEMENTS FLUIDS
KINDRED, ND—2026-06-29
ICE CRYSTAL ENGINEERING
WAYNESVILLE, NC—2026-06-23
161409 - PREMIER MAGNESIA, LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341135820.