Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIDIT DM, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DIDIT DM, LLC in 15 EAST BETHPAGE ROAD, PLAINVIEW, NY 11803 (NAICS 561431). OSHA activity number 341145233.

Watch Didit DM, LLC — free Get an email when a new federal OSHA severe-injury report for Didit DM, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DIDIT DM, LLC
Site address
15 EAST BETHPAGE ROAD
City
PLAINVIEW
State
NY
ZIP
11803
Mailing
330 OLD COUNTRY ROAD, MINEOLA, NY 11501
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561431
Employees
14
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2625.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) Facility - Production Area: On, or about, 12/21/2015 employee conducts maintenance on machinery and other employees operate machines, without an energy control program in place to ensure that procedures, training and periodic inspections were implemented for the prevention of injuries caused by the released of stored energy, including electrical and pneumatic sources.    Machines included, but may not be limited to:  1)         Inserter Machine, 6 x 9 - Aisle # 8;    2)         Inserter Machine, 6 x 9 - Aisle # 9;    3)         Inserter Machine, 6 x 9 - Aisle # 10;    4)         Inserter Machine, 6 x 9 - Aisle # 11.   Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3500

1910.147 C04

Serious Gravity 5 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:       a) Facility - Production Area: On, or about, 12/21/2015 the employer did not develop, document and implemented written specific procedures for  machines having multiple energy sources, such as electrical, and pneumatic.    Machines included, but may not be limited to:    1)         Inserter Machine, 6 x 9 - Aisle # 8;     2)         Inserter Machine, 6 x 9 - Aisle # 9;     3)         Inserter Machine, 6 x 9 - Aisle # 10;     4)         Inserter Machine, 6 x 9 - Aisle # 11.       Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a) Facility - Production Area: On, or about, 12/21/2015 employee services, and conducts maintenance on, machinery without the being trained to control hazardous energy, such as electrical and pneumatic sources. Machines included, but may not be limited to:    1)         Inserter Machine, 6 x 9 - Aisle # 8;     2)         Inserter Machine, 6 x 9 - Aisle # 9;     3)         Inserter Machine, 6 x 9 - Aisle # 10;     4)         Inserter Machine, 6 x 9 - Aisle # 11.       Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3675.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a) Facility - Production Area: On, or about, 12/21/2015 the employer did not ensure guarding for machine areas where hazards existed from ingoing nip points and rotating parts. Machines included, but may not be limited to:  1)         Inserter Machine, 6 x 9  Aisle # 8;    2)         Inserter Machine, 6 x 9  Aisle # 9;    3)         Inserter Machine, 6 x 9  Aisle # 10;    4)         Inserter Machine, 6 x 9  Aisle # 11.   Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3675
  • — Z (S) $4900

1910.219 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed  by guards conforming to the requirements  specified in 29 CFR1910.219 (m) and (o).  29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a) Facility - Production Area: On, or about, 12/21/2015 the employer did not ensure guarding for machine areas where hazards existed from ingoing nip points and rotating parts. Machines included, but may not be limited to:  1)         Inserter Machine, 6 x 9  Aisle # 8;    2)         Inserter Machine, 6 x 9  Aisle # 9;    3)         Inserter Machine, 6 x 9  Aisle # 10;    4)         Inserter Machine, 6 x 9  Aisle # 11.   Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Penalty
Initial $2800.00 · Current $2100.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Facility - Production Area: On, or about, 12/21/2015 the employer did not ensure electrical equipment attached to inserter machines were enclosed. Machines included, but may not be limited to:    1)         Inserter Machine, 6 x 9  Aisle # 10 and;    2)         Inserter Machine, 6 x 9  Aisle # 11.   Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.