Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: XENIA MANUFACTURING, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of XENIA MANUFACTURING, INC in 1507 CHURCH ST., XENIA, IL 62899 (NAICS 335129). OSHA activity number 341146298.

Watch Xenia Manufacturing, INC — free Get an email when a new federal OSHA severe-injury report for Xenia Manufacturing, INC is published. One employer, no account, unsubscribe in one click.
Site address
1507 CHURCH ST.
City
XENIA
State
IL
ZIP
62899
Mailing
P.O. BOX 237, XENIA, IL 62899
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335129
Employees
98
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2082.00 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A-D):    The employer does not ensure that energy control procedures identify the specific steps to follow to isolate and control hazardous energy of machines during servicing and maintenance activities. The employers lockout procedures did not cover:    (1) The magnitude of the electrical and compressed air energy to be controlled.   (2) Procedural steps for an orderly shutdown of the machine.   (3) Procedures for the application of lockout devices.   (4) Procedures for the release of stored energy.  (5) Specific steps for verification that isolation and deenergization has been accomplished.    Employees working to decommission the #4 Komax machine were not provided energy control procedures with specific isolation and control steps and were exposed to the hazard of electrical shock.
Recent events (2)
  • — I (S) $2082
  • — Z (S) $2975

1910.147 C05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2450.00 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    The employer did not ensure that its employees performing servicing and maintenance of equipment were provided a lock and other hardware to isolate equipment from energy sources.  This violation recently occurred on or about December 29, 2015, when employees were exposed to an electrical shock hazard while decommissioning the #4 Komax machine.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.147 F03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft:     The employer did not ensure that a procedure for group lockout was utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when a crew decommissioned the #4 Komax.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2450.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    Employees performed service and maintenance regularly and the employer did not ensure that inspections of the energy control procedures were conducted at least annually to ensure that the procedure and the requirements of this standard are being followed.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.147 F01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof.  In situations in which lockout or tagout devices must be temporarily removed from the energy isolating devices and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of action was not followed:  Employees who performed testing or positioning of machines and equipment were not required to follow the required sequence of actions: (1) Clear the machine or equipment of tools and materials in accordance with paragraph (e)(1) of this section, (2) Remove employees from the machine or equipment area in accordance with paragraph (2) of this section, (3) Remove the lockout or tagout device as specified in paragraph (3) of this section, (4) Energize and proceed with testing or positioning, (5) Deenergize all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and maintenance.  Employees required to rely upon electrical control components for energy control were exposed to electric shock hazards from unexpected start-up and energizing of the #1 Direct Connect Machine during a program change.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

View XENIA MANUFACTURING, INC's full OSHA safety record →