OSHA Inspection: CENTURY MILLWORK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CENTURY MILLWORK in 18927 ALDINE WESTFIELD RD., HOUSTON, TX 77073 (NAICS 321918). OSHA activity number 341159366.

Watch Century Millwork — free Get an email when a new federal OSHA severe-injury report for Century Millwork is published. One employer, no account, unsubscribe in one click.
Establishment
CENTURY MILLWORK
Site address
18927 ALDINE WESTFIELD RD.
City
HOUSTON
State
TX
ZIP
77073
Mailing
18927 ALDINE WESTFIELD RD., HOUSTON, TX 77073
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
15
Ownership type
A

8 citations on file for this inspection.

1910.178 L02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.     On or about January 6, 2016 throughout the shop area, where an employee was operating a forklift without being properly trained and evaluated.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.178 P01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s).      On or about January 6, 2016, throughout the shop area where employees were exposed to struck-by hazards while operating a Nissan forklift, SN: 70362 that was observed to have brake lights and a left turn signal that did not work.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.213 L02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      On or about January 6, 2016, in the shop area where an employee was exposed to a struck-by, caught in between hazard while operating an Accu-Sytems horizontal boring machine SN: 004-07-H23-C-8 without guarding the hold down clamps.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points.      On or about December 1, 2015 in the shop area, where an employee was exposed to caught-in hazards when operating a 6 inch Delta belt sander SN: 87C04790 which had nip points that were not protected by a guard.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.242 B

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about January 6, 2016 throughout the shop area where employees were exposed to struck-by hazards while blowing off equipment without reducing the air pressure below 30 p.s.i.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.303 B07 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:      On or about January 6, 2016 in the shop area, where employees were exposed to electrical hazards when utilizing a 120 volt outlet that was deteriorated due to overheating.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 5 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:      On or about January 6, 2016 at the South east corner of the shop area where employees were exposed to an electrical hazard when using electrical breaker boxes that had unused openings that were not effectively closed.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   On or about January 6, 2016 at the South east corner of the shop area where two breaker boxes were not labeled to identify each breaker and or switch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View CENTURY MILLWORK's full OSHA safety record →