Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEFFREY PIETTE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JEFFREY PIETTE in 324 NORTH MAIN STREET, WOONSOCKET, RI 02895 (NAICS 238390). OSHA activity number 341164986.

Watch Jeffrey Piette — free Get an email when a new federal OSHA severe-injury report for Jeffrey Piette is published. One employer, no account, unsubscribe in one click.
Establishment
JEFFREY PIETTE
Site address
324 NORTH MAIN STREET
City
WOONSOCKET
State
RI
ZIP
02895
Mailing
1340 WOONSOCKET HILL RD, NORTH SMITHFIELD, RI 02896
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $2200.00 Reduced
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.    Job site:  Employees operating a miter saw were exposed to struck by hazards without eye protection.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2400

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $0.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.    Job site:  Employees working on the ground below and adjacent to the decks being constructed were exposed to struck-by falling object hazards.  Employees were not wearing any protective helmets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $2400.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b)    Job site:  Employees working on the second and third floor decks were exposed to falls of approximately 10 - 20 feet and they were not provided with a fall protection system.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $2800

1926.405 A02 II I

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  Job site:  Flexible cord was run under a locked exit door without protection to avoid damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341164986.