Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPIROS INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPIROS INDUSTRIES, INC. in 7666 HWY WW, WEST BEND, WI 53090 (NAICS 332613). OSHA activity number 341169985.

Watch Spiros Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Spiros Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7666 HWY WW
City
WEST BEND
State
WI
ZIP
53090
Mailing
7666 HWY WW, WEST BEND, WI 53090
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332613
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(1):     Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) Employer's lockout program did not clearly distinguish between single energy source, multiple energy source (if any) and cord/plug controlled machines.
Recent events (3)
  • — F (O) $0
  • — C (S) $2975
  • — Z (S) $2975

1910.212 A01

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2975.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)    PC2-1 Spring Forming Machine:  The PC2-1 machine did not have associated mechanical operations guarded, exposing employees to pinching and struck-by hazards.
Recent events (3)
  • — F (S) $2975
  • — C (S) $2975
  • — Z (S) $2975

1910.212 A03 II

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) PC2-1 Spring Forming Machine:  The PC2-1 machine did not have the point of operation effectively guarded, in that the barrier guarding installed allowed inspection personnel and machine set-up operators to reach into the point of operation.  This exposed employees to a pinching and struck-by hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341169985.