Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOAM CO., INC. DBA TRISTATE FOUNDATION WATERPROOFING

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FOAM CO., INC. DBA TRISTATE FOUNDATION WATERPROOFING in 3 CHURCH STREET, TOMKINS COVE, NY 10986 (NAICS 238310). OSHA activity number 341174589.

Watch Foam CO., INC. DBA Tristate Foundation Waterproofing — free Get an email when a new federal OSHA severe-injury report for Foam CO., INC. DBA Tristate Foundation Waterproofing is published. One employer, no account, unsubscribe in one click.
Site address
3 CHURCH STREET
City
TOMKINS COVE
State
NY
ZIP
10986
Mailing
PO BOX 524, BULLVILLE, NY 10915
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
2
Ownership type
A

7 citations on file for this inspection.

1910.1200 H03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:    a) 3 Church Street, Tompkins Cove, NY:   Employees preparing, handling and using Rub-R-Wall Waterproofing (Category 2 Flammable Liquid - Solvent Mixture) were not trained on the physical and health hazards of this chemical; on or about 12/4/15.    b) 3 Church Street, Tompkins Cove, NY:  Employees working inside the back of the truck used a gasoline-powered generator, gasoline-powered air compressor, and a diesel-powered hydraulic airless sprayer and were not trained on the physical and health hazards of the by-products of engine combustion exhaust (e.g., carbon monoxide); on or about 12/4/15.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a) 3 Church Street, Tompkins Cove, NY:   On or about 12/4/15 to 12/5/15, employees prepared, handled and used Rub-R-Wall Waterproofing (Category 2 Flammable Liquid - Solvent Mixture) and the employer did not instruct employees in the following:  1. Procedures and equipment to ground the truck (e.g., copper grounding rod).  2. Procedures and equipment to ground the 55-gallon drums of Rub-R-Wall Waterproofing being used inside the truck.   3. The potential for the accumulation of flammable vapors inside the truck while Rub-R-Wall (Category 2 Flammable Liquid - Solvent Mixture) was being heated, circulated and sprayed and methods to prevent the potential accumulation of flammable vapors.  4. The potential for accumulation of flammable vapors due to the site configuration requiring parking on a hill that could result in the accumulation of flammable vapors inside the cargo area of the truck.  5. Procedures and proper use of equipment to ensure that Rub-R-Wall is not heated above 160 deg. F.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.152 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation:    a) 3 Church Street, Tompkins Cove, NY - Inside the back of the company box truck: On or about 12/4/15 to 12/5/15 Rub-R-Wall Waterproofing (Category 2  Flammable Liquid) was heated and then pumped from a 55-gallon drum within 50 feet of ignition sources (e.g., sparks, hot surface temperatures) associated with the use of an electric cord and plug type Uline H-4931 Heavy Duty Drum Heater, a Honda Generator ES6500 (gasoline-powered motor), an Emglo K5HGA-8P Air Compressor (gasoline-powered motor), and a 2004 Spray Hog Commercial Hydraulic Airless Sprayer or equivalent (diesel powered motor).     b) 3 Church Street, Tompkins Cove, NY - Inside the back of the company box truck:  On or about 12/4/15 to 12/5/15 Rub-R-Wall Waterproofing (Category 2  Flammable Liquid) was heated and then pumped  from an approximately 55-gallon drum within 50 feet of ignition sources (e.g., static electricity) associated with operation of and lack of grounding of a Uline H-4931 Heavy Duty Drum Heater, a Honda Generator ES6500, an Emglo K5HGA-8P Air Compressor and a 2004 Spray Hog Commercial Hydraulic Airless Sprayer or equivalent.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.407 B

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.407(b): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not approved as intrinsically safe or approved for the hazardous (classified) location or safe for the hazardous (classified) location:  a) 3 Church Street, Tompkins Cove, NY - Inside the back of the company box truck:   On or about 12/4/15 to 12/5/15 Rub-R-Wall Waterproofing (Category 2  Flammable Liquid) was heated and then pumped  from a 55-gallon drum using a Uline H-4931 Heavy Duty Drum Heater, a Honda Generator ES6500 (gasoline-powered) and an Emglo K5HGA-8P Air Compressor (gasoline-powered) and a 2004 Spray Hog Commercial Diesel-Powered Hydraulic Airless Sprayer (diesel-powered) that were not approved as intrinsically safe, approved for the hazardous (Class I, Division 2) location or safe for the hazardous (Class I, Division 2) location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:    a)  3 Church Street, Tompkins Cove, NY:   Two employees engaged in waterproofing operations worked inside an excavation approximately 10 feet deep and an inspection of the excavation was not conducted by a competent person prior to the start of the work; on or about 12/4/15.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):    a)  3 Church Street, Tompkins Cove, NY:   Two employees engaged in waterproofing operations worked inside an excavation approximately 10 feet deep that was not protected against cave-ins by an adequate protective system; on or about 12/4/15.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:    a) 3 Church Street, Tompkins Cover, NY:  The employer did not report within twenty-four (24) hours to OSHA an employee in-patient hospitalization that resulted from a work-related fire/explosion incident; on or about 12/5/15.
Recent events (2)
  • — I (O) $1200
  • — Z (O) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341174589.