KARNES CITY, TX —
OSHA Inspection: KAY SERVICES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of KAY SERVICES, INC. in 29.043194,-97.8416667, KARNES CITY, TX 78118 (NAICS 541990). OSHA activity number 341209385.
Where did this inspection happen?
- Establishment
- KAY SERVICES, INC.
- Site address
- 29.043194,-97.8416667
- City
- KARNES CITY
- State
- TX
- ZIP
- 78118
- Mailing
- P.O. BOX 547, WEST COLUMBIA, TX 77486
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541990
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 A
- Issued
- Penalty
- Initial $7000.00 · Current $2100.00 Reduced
General-duty citation text
STANDARD AND AVD CHANGED TO: 29 CFR 1926.21(a): The employer did not establish and/or supervise programs for the education and/or training of employers and/or employees in the recognition, avoidance and prevention of unsafe conditions in employments covered by the act: On or about January 27, 2016, at this pipeline maintenance site, employees were exposed to struck-by/caught-between hazards from a release of pressure on the bucket of the skid steer compact track loader.
Recent events (2)
- — I (S) $2100
- — Z (S) $7000
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 27 January 2016, at this pipeline maintenance site, the employer's energy control procedures were not specific for the skid steer/compact track loader.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed. The employer did not certify periodic inspections had been performed for the skid steer/compact track loader, to ensure all hazardous energy sources were controlled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 541990)
AVALON, CA—2026-04-23
CATALINA ISLAND COMPANY
FORT MADISON, IA—2026-04-15
A09CS00000TXLUFAA4 - WAGGONER SOLUTIONS CO.
HOUSTON, TX—2026-04-14
SAFETY MANAGEMENT SYSTEMS
BOCA RATON, FL—2026-03-27
ALL 1 SERVICE, INC
FLORENCE, NJ—2026-03-25
MUMFORD-BJORKMAN ASSOCIATES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source