ELKHORN, NE —
OSHA Inspection: CASTLE BROOK FRAMING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CASTLE BROOK FRAMING in 625 N. 189TH STREET, ELKHORN, NE 68022 (NAICS 238130). OSHA activity number 341210649.
Where did this inspection happen?
- Establishment
- CASTLE BROOK FRAMING
- Site address
- 625 N. 189TH STREET
- City
- ELKHORN
- State
- NE
- ZIP
- 68022
- Mailing
- 17330 W. CENTER ROAD STE 110-102, OMAHA, NE 68130
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: The employer is failing to protect employees from fall hazards of approximately 12 feet 7 inches on a job site where the employees are finishing fascia work while using a company erected carpenter scaffold with walking platforms that were constructed using 2x12s and measured to be approximately eleven and half inches wide.
Recent events (3)
- — A (S) $2800
- — I (S) $1200
- — Z (S) $2800
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: The employer is failing to protect employees from fall hazards of approximately 12 feet 7 inches on a job site where the employees are finishing fascia work while using a company erected carpenter scaffold that is failing to meet the safety requirements of this subpart as a result of not being inspected prior to use.
Recent events (3)
- — A (S) $2800
- — I (S) $2000
- — Z (S) $2800
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. The employer is failing to protect employees from fall hazards of approximately 12 feet 7 inches on a job site where the employees are finishing fascia work while using a company erected carpenter scaffold that was built without the direction of a competent person. Instances that demonstrate this failure include but are not limited to: i. The platform was constructed out of a 2x12 and measured to be eleven and half inches wide when the standard requires them to be 18 inches wide. ii. The scaffolding has no guard railing installed to protect against fall hazards. iii. The scaffolding was built without diagonal cross bracing to provide lateral support to the system while in use.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: The employer is failing to protect employees from fall hazards of approximately 12 feet 7 inches on a job site where the employees are finishing fascia work while using a company erected carpenter scaffold that is missing guard railing.
Recent events (3)
- — A (S) $2800
- — I (S) $2000
- — Z (S) $2800
1926.452 A04
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds. The employer is failing to protect employees from fall hazards of approximately 12 feet 7 inches on a job site where the employees are finishing fascia work while using a company erected carpenter scaffold that was built without diagonal bracing between the vertical poles.
Recent events (3)
- — A (S) $2800
- — I (S) $2000
- — Z (S) $2800
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in NE
CRETE, NE—2026-07-15
SMITHFIELD FOODS
OMAHA, NE—2026-07-14
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341210649.