Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HST CONTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HST CONTRUCTION, INC. in PUERTO DEL REY MARINA, FAJARDO, PR 00738 (NAICS 237110). OSHA activity number 341212983.

Watch HST Contruction, INC. — free Get an email when a new federal OSHA severe-injury report for HST Contruction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PUERTO DEL REY MARINA
City
FAJARDO
State
PR
ZIP
00738
Mailing
PMB 476, PO BOX 7891, GUAYNABO, PR 00970
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.28 A

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions:   a.  On or about March 25, 2016, At the end of El Varadero, employees are exposed to a struck by hazard while constructing a sump pump station without personal protective equipment such as but not limited to: safety shoes and gloves.     NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.150 C01 VI

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:   a.    On or about March 25, 2016 at the end of El Varadero, employees were exposed to fire hazards while constructing a sump pump station where vehicles, power industrial trucks and boats were in the vicinity and no fire extinguishers were available or provided in case of a sudden fire.      NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a)    On or about March 25, 2016, at the end of El Varadero, employees engaged in the construction of a sump pump station were exposed to an electrical shock hazard of 120 volts from using a portable power drill and circular saw via extension cord without a working GFCI.     b)    On or about March 25, 2016, employees engaged in the construction of a sump pump station were exposed to an electrical shock hazard of 120 volts from using a portable circular saw via extension cord without a working GFCI.     NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341212983.