WHARTON, TX —
OSHA Inspection: WEAVER GLOBAL INDUSTRIES, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of WEAVER GLOBAL INDUSTRIES, LLC in 2.4 MILES NW, WHARTON, TX 77488 (NAICS 213112). OSHA activity number 341221968.
Where did this inspection happen?
- Establishment
- WEAVER GLOBAL INDUSTRIES, LLC
- Site address
- 2.4 MILES NW
- City
- WHARTON
- State
- TX
- ZIP
- 77488
- Mailing
- 6228 COLLEYVILLE BLVD STE A, COLLEYVILLE, TX 76034
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard. At well site Outlar#1, employees exposed to struck-by hazards when circulating the well's high pressure hoses which were missing or not installed correctly with whip checks or other safety devices.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor or platform four feet or more above adjacent floor or ground level were not guarded with standard railing (or equivalent) and toe boards: At well site Outlar #1, employees working from the Rig operator's station were exposed to fall hazards greater than four feet.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.106 B06
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: At well site Outlar #1, employees were exposed to fire and explosion hazards while performing plug and abandoned operations (utilizing a torch) where flammable gases were present.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: At well site Outlar #1, employees were working at the well-bore of a natural gas well during plug and abandoned operations, in which lines were under pressure, and were exposed to the hazard of burns from flash fires without the protections of fire retardant clothing (FRC's).
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: At well site Outlar #1, a hazard assessment was not conducted to determine the need for personal protective equipment such as, but not limited to, fire retardant clothing, safety glasses, hand protection, mask, chemical gloves and chemical aprons. The employees were exposed to corrosive chemicals and natural gases where a flash fire occur.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.145 C03
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): At well site Outlar#1, emergency/warning signs were not erected such as: a. Directional signs with Rig number at entrance in event of an emergency, b. Muster area posted/wind sock, c. Requirements of PPE (Personal Protective Equipment), d. No smoking signs, e. Eye wash location identified with visible sign, hearing protection required warning signs, and f. Fall protection required warning signs were not erected.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.184 F05 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.184(f)(5)(iii): Wire rope sling(s) that had kinking, crushing, bird caging or other damage resulting in distortion of the wire rope structure were not immediately removed from service: At the well site, employees utilized drum line and catline to hoist drilling pipes. The wire ropes showed evidence of crushing, broken wires, and fraying and were not removed out of service. This exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.1200 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(a)(1): The employer did not effectively ensure that the information concerning the hazards of all chemicals to which the employees may be exposed to, was transmitted as accomplished by the means of the employer's comprehensive hazard communication programs including labeling and other forms of warning, material safety data sheets and employee training. At the well site, employees engaged in plug and abandonment operations were exposed to chemical/materials such as, but not limited to natural gas. The employer had not developed a program which would address labeling/warnings on containers and/or dispensaries, Safety Data Sheets, and employee information and training on the hazards associated with the chemical/material exposure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 213112)
COLLBRAN, CO—2026-07-14
LARAMIE ENERGY
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341221968.