OSHA Inspection: PROCON CONSTRUCTIONS SERVICE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROCON CONSTRUCTIONS SERVICE LLC in 1850 P STREET, LINCOLN, NE 68508 (NAICS 238130). OSHA activity number 341223634.

Watch Procon Constructions Service LLC — free Get an email when a new federal OSHA severe-injury report for Procon Constructions Service LLC is published. One employer, no account, unsubscribe in one click.
Site address
1850 P STREET
City
LINCOLN
State
NE
ZIP
68508
Mailing
PO BOX 166, AILEY, GA 30410
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.502 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3150.00 · Current $0.00 Reduced
29 CFR 1926.502(b)(2):     Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high.      The employer is failing to protect employees from fall hazards when they are working in the vicinity of a ladder system and floor hole.  This was most recently documented at 1850 P Street, Lincoln NE, 2nd Floor, where employees were observed in the area of guardrail systems constructed without mid rails.  The guardrails were installed around ladder access points and constructed with lumber (2X4) consisting of top-rails and vertical members.  The floor holes each had falls to the next lower level of over 9 feet.         a.  2nd floor East Ladder access point; mid-rails were not installed.                                                                                              b.  2nd floor West Ladder access point; mid-rails were not installed.         Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3150

1926.502 B03

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(b)(3):     Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:    The employer is failing to protect employees from fall hazards when they are working in the vicinity of a ladder system and floor hole.  This was most recently documented at 1850 P Street, Lincoln NE, 2nd Floor East Ladder access, when employees were observed in the area of a guardrail system which was not built to withstand 200 pounds of force.  The guardrail system was constructed with lumber (2X4) and withstood minimal pressure before exhibiting signs of failure.         Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $1900.00
29 CFR 1926.502(b)(13):     When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole:    The employer is failing to protect employees from fall hazards when they are working in the vicinity of a ladder system and floor hole.  This was most recently documented at 1850 P Street, Lincoln Nebraska, where employees were observed in the area of guardrail systems built to prevent falls into a ladder hole.  The guardrail systems on the 2nd floor were not equipped with either gates or offset guardrails.  The floor holes each had falls to the next lower level of over 9 feet.         a.  2nd floor East Ladder access point; there was not any type of offset guardrail or gate.       b.  2nd floor West Ladder access point; there was not any type of offset guardrail or gate.          Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $0