CHEBOYGAN, MI —
OSHA Inspection: DEPARTMENT OF HOMELAND SECURITY, U.S. COAST GUARD, MILLER D. OLDS MOORING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEPARTMENT OF HOMELAND SECURITY, U.S. COAST GUARD, MILLER D. OLDS MOORING in 632 COAST GUARD DRIVE, CHEBOYGAN, MI 49721 (NAICS 928110). OSHA activity number 341230084.
Where did this inspection happen?
- Site address
- 632 COAST GUARD DRIVE
- City
- CHEBOYGAN
- State
- MI
- ZIP
- 49721
- Mailing
- 632 COAST GUARD DRIVE, CHEBOYGAN, MI 49721
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 7
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.36 D01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(d)(1) as required by 1960.8(b): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: In the electrical shop, the fire exit door was locked and required a key to open it, there by exposing employees to a fire hazard.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii) as required by 1960.8(b): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: Employer did not provide and maintain sufficient access could hinder the ready and safe operation and maintenance of equipment. (a) MK Shop, the working area in front of the electrical distribution panel was used for storage of items, such as but not limited to: welder and scale. The U.S. Coast Guard was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(g)(1)(ii) which was contained in OSHA inspection number 972310, citation number 1, item number 1 and was affirmed as a final order on June 24, 2014 with respect to a workplace located at 1175 Airport Access Road, Traverse City, MI 49686.
Recent events (1)
- — Z (R) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a. On or about January 14, 2016, the employer failed to re-evaluate Powered Industrial Truck Operator perfomance. One operator's three year certification expired on October 31, 2010.
Recent events (1)
- — Z (O) $0
1960.25 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1960.25(c): The Agency did not inspect annually, all areas in each workplace, including office operations: U.S. Coast Guard, Miller D. Olds Mooring, the employer did not conduct annual workplace evaluation.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 928110)
FORT LEE, VA—2026-07-15
U.S. DEPARTMENT OF THE ARMY - FORT LEE
COLUMBIA, SC—2026-07-02
U.S. DEPARTMENT OF VETERANS AFFAIRS
COLUMBIA, SC—2026-07-02
U.S. DEPT OF ARMY
COLUMBIA, SC—2026-07-02
U.S. DEPT OF ARMY
EL PASO, TX—2026-06-24
U.S. CUSTOMS AND BORDER PROTECTION
More inspections in MI
FLINT, MI—2026-07-16
WILDFIRE INVESTMENT LLC
MUSKEGON, MI—2026-07-16
TIMBERLAND CHARTER ACADEMY
ROCHESTER HILLS, MI—2026-07-16
LEAR CORPORATION DBA EAGLE OTTAWA
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341230084.