OSHA Inspection: JUAN SEGURA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN SEGURA in 7716 OTTAWA LANE, WEST CHESTER, OH 45069 (NAICS 238160). OSHA activity number 341233526.

Watch Juan Segura — free Get an email when a new federal OSHA severe-injury report for Juan Segura is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN SEGURA
Site address
7716 OTTAWA LANE
City
WEST CHESTER
State
OH
ZIP
45069
Mailing
7614 MCKINNEY MEADOWS DR., MCKINNEY, TX 75071
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  Located on the north side of a residential low pitch roof structure, employees were observed installing shingles while not utilizing any fall protection system. Potential fall height was measured in excess of 18' with a roof pitch of 4 in 12.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.