CORAOPOLIS, PA —
OSHA Inspection: CHAMP PRINTING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHAMP PRINTING COMPANY, INC. in 730 4TH AVENUE, CORAOPOLIS, PA 15108 (NAICS 323111). OSHA activity number 341242659.
Where did this inspection happen?
- Establishment
- CHAMP PRINTING COMPANY, INC.
- Site address
- 730 4TH AVENUE
- City
- CORAOPOLIS
- State
- PA
- ZIP
- 15108
- Mailing
- 730 4TH AVENUE, CORAOPOLIS, PA 15108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 37
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 A04
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Main press room, 730 4th Avenue, Coraopolis, PA 15108: On or about February 10, 2016, the employer did not obtain prior written approval from the forklift manufacturer for the use of a wooden platform used to elevate employees on a Hyster brand forklift (model number S50E, serial number D002D10414B) in the main press room. Employees lifted on the forklift platform were exposed to a fall hazard of up to approximately 20 feet to the concrete floor below.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Jobsite, 730 4th Avenue, Coraopolis, PA 15108: Observed on or about February 10, 2016, the employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were being followed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space about electric equipment rated 600 volts, nominal, or less was used for storage: a) Back of shop near book binder, 730 4th Avenue, Coraopolis, PA 15108: Observed on or about February 10, 2016, access to electrical panels located near the book binder in the back of the shop was restricted by the storage of several hoppers. Each hopper contained paper products that were awaiting to be recycled. The electrical panels were used to supply power to various type of equipment throughout the facility.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 IX
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard: a) Main press room, 730 4th Avenue, Coraopolis, PA 15108: Observed on or about February 10, 2016, the light bulbs on a light fixture located near a storage rack used to store a forklift basket were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. The forklift operates within a few inches of the light fixture while moving a forklift basket. Employees were exposed to the hazards of electric shock and cuts and scrapes from broken glass in the event that the light bulbs would break.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CHAMP PRINTING COMPANY, INC.
CORAOPOLIS, PA—1994-06-29 00:00:00
CHAMP PRINTING COMPANY, INC.
View CHAMP PRINTING COMPANY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
MUSKEGON, MI—2026-07-08
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02
INNOTECH LASER
HERMITAGE, PA—2026-07-01
CCL CONTAINER, INC.
GREEN BAY, WI—2026-06-30
CHARTER NEXT GENERATION, INC.
LEHI, UT—2026-06-25
FIVE INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source