ATLANTA, GA —
OSHA Inspection: ECUA BUILDERS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ECUA BUILDERS, INC. in 4126 CONWAY VALLEY ROAD, ATLANTA, GA 30327 (NAICS 238130). OSHA activity number 341250355.
Where did this inspection happen?
- Establishment
- ECUA BUILDERS, INC.
- Site address
- 4126 CONWAY VALLEY ROAD
- City
- ATLANTA
- State
- GA
- ZIP
- 30327
- Mailing
- 1231 OAK ARBOUR AVENUE, LAWRENCEVILLE, GA 30044
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.304 D
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: (a) Second floor, new residential construction located at 4126 Conway Valley Road, Atlanta, GA 30327: Employees were exposed to severe laceration and amputation hazards while operating a Makita (Model -5007NB) 7-1/4-inch Circular Saw without an operating lower guard as a wood shim was used to keep the lower guard in a fixed open position.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.403 B02
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Second floor, new residential construction located at 4126 Conway Valley Road, Atlanta, GA 30327: Employees were exposed to electrical shock hazards while using an electrical junction box which was connected to a flexible cord and used as a makeshift power outlet. The junction box used is intended for indoor use and is manufactured to be fixed to a support within a structure.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.405 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: (a) Second floor, new residential construction located at 4126 Conway Valley Road, Atlanta, GA 30327: Employee was exposed to electrical shock hazards while using an energized junction box which was not provided with a cover over the outlet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) Second floor, new residential construction located at 4126 Conway Valley Road, Atlanta, GA 30327: Employees were exposed to fall hazards of approximately 15-feet, 8-inches to the concrete surface below while working on a makeshift scaffold with no fall protection system in place.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.403 B01
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $240.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) New residential construction located at 4126 Conway Valley Road, Atlanta, GA 30327: The employer failed to inspect all of the electrical cords prior to the start of the work shift. Multiple extension cords were missing ground pins, strain relief and had torn outer protective casings and were not removed from service or repaired.
Recent events (2)
- — I (O) $240
- — Z (O) $400
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341250355.