Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHIZEK TRANSPORT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHIZEK TRANSPORT, INC. in 5002 COUNTY ROAD F, NEWTON, WI 53063 (NAICS 484121). OSHA activity number 341254902.

Watch Chizek Transport, INC. — free Get an email when a new federal OSHA severe-injury report for Chizek Transport, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5002 COUNTY ROAD F
City
NEWTON
State
WI
ZIP
53063
Mailing
P.O. BOX 147, CLEVELAND, WI 53015
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
120
Ownership type
A

8 citations on file for this inspection.

1910.23 E01

Serious Gravity 5 2 instances 11 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1836.00 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:    a)    On or about 2/17/2016, The shop mezzanine had hand rails without mid rails above the tire storage area and by the stairway.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.23 E04

Serious Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(e)(4): 29 CFR 1910.23(e)(4): A standard toeboard was not provided with a 4 inches nominal in vertical height from its top edge to the level of the floor and securely fastened in place and with not more than 1/4 inch clearance above the floor level.  a)    On or about 2/17/2016, Mezzanine railing above the uniform room did not have a toe board.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1836.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):      a)    On or about 2/17/2016, the company was not performing an evaluation of each operators competence to drive lift truck when hired and at least every three years there after.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.215 A04

Serious Gravity 1 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a)    On or about 2/17/2016, the pedestal grinder in the tire storage area had a 3/4" gap between the tool rest and the stone.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.215 B09

Serious Gravity 1 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a)    On or about 2/17/2016, the pedestal grinder in the tire storage area had a 1/2" gap between the tongue guard and the stone.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J01 I

Serious Gravity 5 2 instances 11 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1836.00 Reduced
29 CFR 1910.305(j)(1)(i): Rosettes and cleat-type lampholders and receptacles located less than 2.44 m (8 feet) above the floor had exposed terminals:    a)    On or about 2/17/2016, The North wall of the shop had worn and damaged receptacles.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.334 A03 I

Serious Gravity 5 2 instances 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:   a)    On or about 2/17/2016, The shop had worn and damaged extension cords that were missing ground pins.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)    On or about 2/17/2016, a work bench on the south wall of the shop had an extension light with a bad outer  cover that had not been taken out of service or replaced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341254902.