NEWTON, WI —
OSHA Inspection: CHIZEK TRANSPORT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHIZEK TRANSPORT, INC. in 5002 COUNTY ROAD F, NEWTON, WI 53063 (NAICS 484121). OSHA activity number 341254902.
Where did this inspection happen?
- Establishment
- CHIZEK TRANSPORT, INC.
- Site address
- 5002 COUNTY ROAD F
- City
- NEWTON
- State
- WI
- ZIP
- 53063
- Mailing
- P.O. BOX 147, CLEVELAND, WI 53015
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 120
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.23 E01
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a) On or about 2/17/2016, The shop mezzanine had hand rails without mid rails above the tire storage area and by the stairway.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.23 E04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(e)(4): 29 CFR 1910.23(e)(4): A standard toeboard was not provided with a 4 inches nominal in vertical height from its top edge to the level of the floor and securely fastened in place and with not more than 1/4 inch clearance above the floor level. a) On or about 2/17/2016, Mezzanine railing above the uniform room did not have a toe board.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about 2/17/2016, the company was not performing an evaluation of each operators competence to drive lift truck when hired and at least every three years there after.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1377.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about 2/17/2016, the pedestal grinder in the tire storage area had a 3/4" gap between the tool rest and the stone.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 2/17/2016, the pedestal grinder in the tire storage area had a 1/2" gap between the tongue guard and the stone.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J01 I
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Rosettes and cleat-type lampholders and receptacles located less than 2.44 m (8 feet) above the floor had exposed terminals: a) On or about 2/17/2016, The North wall of the shop had worn and damaged receptacles.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.334 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: a) On or about 2/17/2016, The shop had worn and damaged extension cords that were missing ground pins.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) On or about 2/17/2016, a work bench on the south wall of the shop had an extension light with a bad outer cover that had not been taken out of service or replaced.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 484121)
YUMA, AZ—2026-07-07
RFX2026XMG193X0063 - HOGAN DEDICATED SERVICES LLC DBA HOGAN TRANSPORTS
OAKLAND, CA—2026-07-07
ROEHL TRANSPORT, INC.
CHARLOTTE, NC—2026-07-06
161495 - FATHER - SONS LLC
SMYRNA, TN—2026-07-06
SILK WAY TRANSPORT, INC
KELLER, TX—2026-06-29
SHOW 1 LOGISTICS
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341254902.