Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROBERT MCHAM LTD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROBERT MCHAM LTD in 6621 N. FM 1788, MIDLAND, TX 79707 (NAICS 811118). OSHA activity number 341269116.

Watch Robert Mcham LTD — free Get an email when a new federal OSHA severe-injury report for Robert Mcham LTD is published. One employer, no account, unsubscribe in one click.
Establishment
ROBERT MCHAM LTD
Site address
6621 N. FM 1788
City
MIDLAND
State
TX
ZIP
79707
Mailing
P.O. BOX 1345, LEVELLAND, TX 79336
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811118
Employees
24
Ownership type
A

17 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $1620.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.    The employer did not ensure an emergency shower or eyewash was available for employees, in the maintenance shop, working with chemicals and exposed them to adverse health effects.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $3240

1910.215 A01

Deleted Serious Gravity 5 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s).  The employer did not ensure bench grinders in the maintenance shop had safety guards for employees engaged in work and exposed them to struck-by hazards in the following instances:  a) On a black Craftsman bench grinder  b) On a red Dayton bench grinder
Recent events (2)
  • — I (S) $0
  • — Z (S) $3240

1910.215 A04

Deleted Serious Gravity 5 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work.  The employer did not ensure bench grinders in the maintenance shop were equipped with work rests and exposed employees to struck-by hazards in the following instances:  a) On a black Craftsman bench grinder  b) On a red Dayton bench grinder
Recent events (2)
  • — I (S) $0
  • — Z (S) $3240

1910.219 D01

Deleted Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $0.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a).  The employer did not ensure the drill press in the maintenance shop was guarded while employees operated the equipment and exposed them to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3240

1910.219 E01 I

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o).  The employer did not ensure belts on a drill press were guarded and exposed employees operating the equipment to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $1620.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1/2 hour rating.    The employer did not ensure oxygen and acetylene tanks were separated in the maintenance shop and exposed employees to explosion and fire hazards.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $3240

1910.303 G02 I

Serious Gravity 10 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $5670.00 · Current $2835.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    The employer did not ensure electrical wiring in the maintenance shop was guarded and exposed employees to electrical shock hazards in the following instances:    a) On the rear wall of the maintenance shop    b) In the bathroom wall of the maintenance shop
Recent events (2)
  • — I (S) $2835
  • — Z (S) $5670

1910.305 B01 II

Serious Gravity 5 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $3240.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer did not ensure electrical parts and wiring were enclosed in the maintenance shop and exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $3240

1910.305 B03 I

Serious Gravity 10 11 instances 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(3)(i): Pull and junction boxes used on systems rated over 600 volts, nominal, did not provide a complete enclosure for the contained conductors or cables:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards due to the lack of covers in the following instances:  a) On an outlet located on the rear wall of the office connected to a microwave  b) On an outlet located by the entryway into the maintenance shop  c) On an outlet located on the rear wall of the maintenance shop bathroom  d) On an outlet located on a side wall in the maintenance shop bathroom  e) On an outlet located on the back wall behind a storage rack in the maintenance shop (left side)  f) On an outlet located on the back wall behind a storage rack in the maintenance shop (right side)  g) On an outlet located on the back wall of the maintenance shop below a junction box  h) On an outlet located on the front wall by the bay doors in the maintenance shop   I) On an outlet located on the front wall of the compressor room   j) On an outlet located on the back wall of the compressor room   k) On an outlet located on the side wall of the compressor room
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 C02

Serious Gravity 5 4 instances 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(c)(2): Flush snap switches that were mounted in ungrounded metal boxes and located within reach of conducting floors or other conducting surfaces were not provided with face plates of nonconducting, noncombustible material:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards due to the lack of protective covers in the following instances:  a) On a snap switch located by the entryway to the maintenance shop  b) On a snap switch located by the entryway to the office  c) On a snap switch located on a black Craftsman bench grinder  d) On a snap switch located on a red Dayton bench grinder
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 10 8 instances 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards due to the use of flexible cables as a substitute for fixed wiring in the following instances:  a) Flexible cable located above the entryway into the office  b)  Flexible cable located behind the maintenance shop  c)  Flexible cable located behind the maintenance shop running into the white storage room  d)  Flexible cable located on the back wall of the shop next to the compressor room  e)  Flexible cable located in the compressor room connected to a Black Max air compressor  f)  Flexible cable located in the compressor room running through the window  g)  Flexible cable located on the back of the maintenance shop wall  h)  Flexible cable located next to the entryway to the office
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards while using a flexible cable that ran through the back wall of the maintenance shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV C

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings.  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards while using flexible electrical cords that ran through a window in the compressor room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:   In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards while using flexible electrical cords attached to the door supports next the entry to the office.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards while using flexible electrical cords containing splices from being run over.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  In the maintenance shop, employees engaged in maintenance activities were exposed to electrical shock hazards while using equipment that did not have strain relief in the following instances:  a) On a Black Max air compressor in the compressor room  b) On a Craftsman bench grinder
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F09

Deleted Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $0.00 Reduced
29 CFR 1910.1200(f)(9): The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:  The employer did not ensure chemical containers in the back of a truck were labeled and exposed employees to adverse health effects.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3240

View ROBERT MCHAM LTD's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341269116.