Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JVE CONTRACTING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JVE CONTRACTING INC. in 58 DELAWARE AVE., LONG BEACH, NY 11561 (NAICS 238170). OSHA activity number 341282770.

Watch JVE Contracting INC. — free Get an email when a new federal OSHA severe-injury report for JVE Contracting INC. is published. One employer, no account, unsubscribe in one click.
Site address
58 DELAWARE AVE.
City
LONG BEACH
State
NY
ZIP
11561
Mailing
527 HOFFMAN LANE, HAUPPAUGE, NY 11788
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  Worksite, 58 Delaware Ave. Long Beach NY - Employees were installing exterior caping a two story residential home while working directly on the edge of the roof.  The employees were not provided with fall protection and were exposed to falling approximately 20ft to the ground below; on or about 2/27/16.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   a) Worksite -  Employees used a 10ft A-frame ladder in the closed position to gain access to the work area; on or about 2/27/16.   Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1360.00 · Current $500.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:      a)  Worksite, 58 Delaware Ave. Long Beach NY - Employees were accessing the roof of a two story residential home by using an extension ladder that was extended approximately 1ft above the landing; on or about 2/27/16.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1360

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341282770.