PITTSBURGH, PA —
OSHA Inspection: JIM LEE CONTRACTING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JIM LEE CONTRACTING in 4489 OHIO RIVER BOULEVARD, PITTSBURGH, PA 15202 (NAICS 238160). OSHA activity number 341286540.
Where did this inspection happen?
- Establishment
- JIM LEE CONTRACTING
- Site address
- 4489 OHIO RIVER BOULEVARD
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15202
- Mailing
- 635 EUREKA STREET, PITTSBURGH, PA 15210
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system, or on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system]: a) Job site, 4489 Ohio River Boulevard, Pittsburgh, PA: On or about February 29, 2016, during roofing work, the employer did not ensure that fall protection systems/devices were in use where fall hazards of up to approximately 25 feet existed.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder were not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a) Job site, 4489 Ohio River Boulevard, Pittsburgh, PA: On or about February 29, 2016, during roofing work, the employer did not ensure that the ladder used for access to/egress from the roof, was properly set up for use in that it was only extended approximately 2 feet above the landing surface.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341286540.