LARGO, FL —
OSHA Inspection: TIMBERLAND DOOR, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIMBERLAND DOOR, LLC in 12555 ENTERPRISE BOULOVARD, LARGO, FL 33773 (NAICS 337212). OSHA activity number 341286771.
Where did this inspection happen?
- Establishment
- TIMBERLAND DOOR, LLC
- Site address
- 12555 ENTERPRISE BOULOVARD
- City
- LARGO
- State
- FL
- ZIP
- 33773
- Mailing
- 12555 ENTERPRISE BOULEVARD, LARGO, FL 33773
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 62
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative a. At the establishment, employees were exposed to amputation and crushing hazards, in that, there was no lock out tag out program in place to prevent the release of stored energy while repairing machinery, such as but not limited to: the Boarke Sander model # BKM-37 K and S/N FC95380; Router RT#2 Model # NC-1925 PT/TC2 and S/N FAANCPT96054; Hoffman Saw model #MS35SF; Router Model # M30120000; Rockwell radial saw model #14-RAS; and ResawSR900, on or about 02/25/2016.
Recent events (1)
- — Z (S) $4900
1910.213 B03
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a. In the molding area, employees were exposed to an amputation hazard, in that, the SR-900 resaw would resume operation after it was powered down and restarted, on or about 02/25/2015.
Recent events (1)
- — Z (S) $4900
1910.213 H01
- Issued
- Penalty
- Initial $3500.00 · Current $3500.00
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material: a. In the molding area, employees were exposed to an amputation hazard, in that, there was no lower guard on the Rockwell model #14 RAS, S/N FC-1893 used to cut molding, on or about 02/25/2015.
Recent events (1)
- — Z (S) $3500
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a. At the establishment, the employer did not have a written assessment of the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE), on or about, 02/25/2016.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 337212)
COLORADO SPRINGS, CO—2026-07-06
EDEN OAKS DESIGNER WOODWARE
PEACHTREE CORNERS, GA—2026-07-02
FINEST FABRICATION LLC.
AUBURN, NH—2026-06-25
TRICKETT WOODWORKS CO
ATHENS, TX—2026-06-25
LEBEAU AND ASSOCIATES, INC.
SPARKS, NV—2026-06-02
VICTORY WOODWORKS INC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source