NAPERVILLE, IL —
OSHA Inspection: ROBERT DOBSON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROBERT DOBSON in 48 CHICAGO AVE., NAPERVILLE, IL 60564 (NAICS 238170). OSHA activity number 341312866.
Where did this inspection happen?
- Establishment
- ROBERT DOBSON
- Site address
- 48 CHICAGO AVE.
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60564
- Mailing
- 893 TOM O'SHANTER CT., BOLINGBROOK, IL 60440
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On or about March 7, 2016, employees performing siding installation operations were exposed to struck by hazards while employees handed equipment and material to the second level from the first level. The employer failed to mandate the use of hard hats. Abatement certification is required of this item in accordance with requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1600
1926.106 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.106(a): Employees working over or near water, where the danger of drowning exists, shall be provided with U.S. Coast Guard-approved life jacket or buoyant work vests. On or about March 7, 2016, employees performing siding installation were exposed to drowning hazards while working over or near water when the employer failed to provide U.S. Coast Guard-approved life jacket or buoyant work vests. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $2000
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about March 7, 2016, employees performing siding installation were exposed to fall hazards greater than 6 feet and the employer did not ensure employees were utilizing fall protection. Abatement certification is required in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.106 C
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.106(c): Ring buoys with at least 90 feet of line shall be provided and readily available for emergency rescue operations. Distance between ring buoys shall not exceed 200 feet. On or about March 7, 2016, employees performing siding installation were exposed to drowning hazards while working over or near water when the employer failed to provide ring buoys with at least 90 feet of line for emergency rescue operations. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $2000
1926.106 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.106(d): At least one lifesaving skiff shall be immediately available at locations where employees are working over or adjacent to water. On or about March 7, 2016, employees performing siding installation were exposed to drowning hazards while working over or near water when the employer failed to provide at least one lifesaving skiff. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $0
1926.416 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. On or about March 7, 2016, employees performing siding installation were exposed to electrical hazards when the employer failed to ensure employees were protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source